12:6 OUTLET AIR SENSOR - SHORT-CIRCUITED
The error code is shown if the analog input OULET AIR TEMP (NTC) is reading a resistance of less than 330 Ω.
Probably caused by broken NTC sensor or damaged wiring.
If the outlet air temperature in the SHOW INPUTS menu shows a temperature of 100 °C the outlet air sensor is
shorted.
When the outlet air sensor is restored the error code is automatically reset and the ongoing program will continue.
A long press on the control knob/start button will make the control system reset and ongoing program will be ended.
The error code can be trigged if:
• The sensor, harness or connector is broken. The sensor shall measure around 5 K Ohm in room temperature, see
table. (Measure direct over the sensor).
If the measure of outlet air sensor is OK, but there is still an error code:
• Check the harness, connectors and functions by reading the electrical schematic and by using the SHOW INPUTS
menu when the machine is in service mode.
Temp - Sensor resistance
-10 °C - 26.7 kΩ
15 °C - 7.6 kΩ
20 °C - 6.0 kΩ
25 °C - 4.8 kΩ
30 °C - 3.9 kΩ
100 °C - 0.33 kΩ
12:8 CONDENSE WATER CONTAINER IS FULL
The pump will run when a program starts for normally 15 seconds. Then it will run again after normally 3 minutes.
The pump will also run if the input for the float is trigged.
The error code is activated if the input CONDENSER TANK is still activated after 15 seconds.
This means that the pump has tried to empty the condense water container without the signal from the float in the
condense water container has been deactivated.
When the float in the condense water container is restored it is possible to reset the error code from the control
system.
The error code is reset from the control system by a short press on the control knob/start button. A long press on the
control knob/start button will make the control system reset and ongoing program will be ended.
The error code can be trigged if:
• The condense water container is full and the pump is not operating. Check the pump by activating the CONDENSER
PUMP menu in the ACTIVATE OUTPUTS menu when the machine is in service mode.
• If the pump is running and no water is coming out, the drain is blocked or the float is out of order.
• If water coming out of the hose, it might be partly blocked.
If the pump does not run or if there is no level in the condense water container check the harness, connectors and
functions by reading the electrical schematic and by using the SHOW INPUTS menu when the machine is in service
mode.
12:9 HEAT PUMP LOW PRESSURE
The error code is shown if the input HP LOW PRESSURE (low pressure switch, P2) has tripped.
The error code can be trigged if there is too little refrigerant in the heat pump or by damaged wiring or connectors.
It can can also be trigged if machine is started in a cold environment, or started with clogged lint filters.
The error can be restored with the knob when the pressure is restored and the ongoing program will continue.
Recommended actions:
1. Check the harness, connectors and functions by reading the electrical schematic and by using the SHOW INPUTS
menu when the machine is in service mode.
2. Check airflow and clean filters.
3. Try to run again, if error still present, check the heat pump for gas leakage.