Electrolux W5105H Installation Manual

Electrolux W5105H Installation Manual

Type w3
Hide thumbs Also See for W5105H:

Advertisement

Installation manual
Washer extractor
W565H, W575H, W5105H, W5130H, W5180H,
W5240H, W5300H
Type W3...
438 9055-20/EN
2013.02.21
Original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux W5105H

  • Page 1 Installation manual Washer extractor W565H, W575H, W5105H, W5130H, W5180H, W5240H, W5300H Type W3... 438 9055-20/EN 2013.02.21 Original instructions...
  • Page 3: Table Of Contents

    1 Safety Precautions ......................5 1.1 Symbols........................5 2 Technical data ........................6 2.1 Drawing ........................6 2.1.1 W565H, W575H, W5105H .................. 6 2.1.2 W5130H ......................7 2.1.3 W5180H, W5240H, W5300H ................8 2.2 Technical data......................9 2.3 Connections........................ 9 2.4 Sound levels .......................
  • Page 5: Safety Precautions

    Safety Precautions 1 Safety Precautions The machine is only intended for water-wash use. Only use detergent intended for water-wash of textiles. Never use dry cleaning agents. Do not allow minors to use the machine. Do not hose down the machine with water. The machine's door lock must under no circumstances be bypassed.
  • Page 6: Technical Data

    Technical data 2 Technical data 2.1 Drawing 2.1.1 W565H, W575H, W5105H fig.7647A Operating panel Door opening, W565H, W575H: ⌀ 310 mm, W5105H: ⌀ 365 mm Detergent container Cold water Hot water Hard water Drain valve Liquid detergent supply Electrical connection...
  • Page 7: W5130H

    Technical data 2.1.2 W5130H fig.7782 Operating panel Door opening, W5130H: ⌀ 395 mm Detergent container Cold water Hot water Hard water Drain valve Liquid detergent supply Electrical connection Steam connection W5130H 1322 1370 1074 1273 W5130H 1253 1153...
  • Page 8: W5180H, W5240H, W5300H

    Technical data 2.1.3 W5180H, W5240H, W5300H fig.7648A Operating panel Door opening, W5180H, W5240H, W5300H: ⌀ 435 mm Detergent container Cold water Hot water Drain valve Liquid detergent supply Electrical connection Steam connection W5180H 1495 1456 1160 1359 W5240H 1022 1540 1490 1195 1393...
  • Page 9: Technical Data

    Technical data 2.2 Technical data W565H W575H W5105H W5130H W5180H W5240H W5300H Weight, net Drum volume litres Drum diameter Drum speed during wash Drum speed during 1245 1245 1165 1115 1055 1005 extraction G-factor, max. Heating: Electricity Heating: Steam Heating: Hot water Frequency of the dynamic 20.8...
  • Page 10: Sound Levels

    The sound power level of the machine is determined by using ISO 3747:2012. According to test code IEC 60704-2-4 the sound power level at extraction and during washing are according to the table: W565H W575H W5105H W5130H W5180H W5240H W5300H...
  • Page 11: Setup

    Setup 3 Setup 3.1 Unpacking 3.1.1 W565H, W575H, W5105H The machine is delivered complete with expander bolts, supporting feet etc. The machine is delivered bolted onto the transport pallet and packed in a crate or box. Remove packing from the machine.
  • Page 12 Setup Remove the machine from the pallet. Note! When moving the machine, handle it with care. Make sure that the machine does not come down on the floor with either of the rear corners first. The side panel of the machine can be damaged.
  • Page 13: W5130H, W5180H, W5240H, W5300H

    Setup 3.1.2 W5130H, W5180H, W5240H, W5300H Note! Two persons are recommended for the unpacking. The machine is delivered complete with expander bolts, supporting feet etc. The machine is delivered bolted onto the transport pallet and packed in a crate or box. Remove packing from the machine.
  • Page 14 Setup Remove the machine from the pallet. Note! When moving the machine, handle it with care. Place the machine on its final position. Mount the supporting feet. W5300H: Note the position of the two front feet. ⑥ W5300H fig.7653A Remount the panels.
  • Page 15: Siting

    Setup 3.2 Siting Install the machine close to a floor drain or open drain. The machine should be positioned so that there is plenty of room for working, both for the user and service personnel. The figure shows minimum distance to a wall and/or other machines. ⑦...
  • Page 16: Mechanical Installation

    The table shows the correct drilling points. W565H-W5105H: Mark and drill two holes (⌀ 8 mm) about 40 mm deep in the positions shown. W5130H-W5300H: Mark and drill two holes (⌀ 10 mm) about 50 mm deep in the positions shown.
  • Page 17: Water Connection

    Water type Water connection W565H, W575H W565H, W575H • Cold 1. Cold W565H, W575H, W5105H, W5130H W565H, W575H, W5105H, W5130H • Cold and hot 1. Cold 2. Hot W5180H, W5240H, W5300H W5180H, W5240H, W5300H •...
  • Page 18 Water connection For installations in UK: WRAS-approved machines must be equipped with check valves on both cold and hot water inlet.
  • Page 19: Connection Of External Dosing Systems

    Connection of external dosing systems 5 Connection of external dosing systems 5.1 Connection of the hoses The machine is prepared for connection of external dosing systems or water re-use systems etc. The connections are closed at delivery. Open any of the connections that shall be used by drilling a hole where the hoses shall be connected.
  • Page 20: Electrical Connection Of External Dosing System

    Connection of external dosing systems 5.2 Electrical connection of external dosing system The power supply to the external dosing system must never be connected to the machine’s incoming terminal block or to the edge connectors on the I/O-board. 5.2.1 Machine with connectors Connect the external dosing system to connections A and B on the machine.
  • Page 21: Machine Without Connectors

    Connection of external dosing systems 5.2.2 Machine without connectors Connect the external dosing system to the I/O board, which is located to the right of the incoming power supply. The I/O board has edge connectors for connecting external dosing systems. Edge connectors on the I/O board can be loosened for connecting cables.
  • Page 22: Outputs

    Connection of external dosing systems 5.2.3 Outputs Connect the power supply (e.g. 24V DC) for the external liquid supplies to 9 and 10. If an internal power supply (from the machine) is being used, it can be taken from 1 (N) and connected to 9 and from 2 (L) and connected to 10.
  • Page 23: Inputs

    Connection of external dosing systems 5.2.4 Inputs The signal level can be 5-24V DC/AC or 100- 240V AC. For 5-24V, the signal reference is connected to 3 and for 100-240V to 4. Potentials on the inputs cannot be mixed. Note! The I/O board will be damaged if the voltage on connection 3 is too high >...
  • Page 24: Drain Connection

    Drain connection 6 Drain connection Connect a 75 mm (50 mm for models W565-W5105) pipe or rubber hose to the machine’s drain pipe, ensuring a downward flow from the machine. Avoid sharp bends which may prevent proper draining. The drainage pipe should be located over a floor drain, drainage channel or the like so that the distance between the outlet and the drain is at least 25 mm.
  • Page 25: Electrical Connection

    Electrical connection 7 Electrical connection 7.1 Electrical installation The electrical installation may only be carried out by qualified personnel. Machines with frequency-controlled motors can be incompatible with certain types of earth leakage circuit breaker. It is important to know that the machines are designed to provide a high level of personal safety, which is why items of external equipment such as earth leakage circuit breakers are not necessary.
  • Page 26: Electrical Connections

    Electrical connection 7.2 Electrical connections W565H Heating alternative Main voltage Heating power Total power Recommended fuse Electric heated 200V 3 ~ 50/60 220–240V 1 ~ 50/60 1.7–2.0 1.8–2.1 220–240V 1 ~ 2.5–3.0 2.7–3.1 50/60 220–240V 1 ~ 50/60 3.7–4.3 3.8–4.5 220–240V 1 ~ 50/60 4.5–5.4...
  • Page 27 Electrical connection W575H Heating alternative Main voltage Heating power Total power Recommended fuse Electric heated 200V 3 ~ 50/60 220–240V 1 ~ 50/60 1.7–2.0 1.8–2.1 220–240V 1 ~ 50/60 2.5–3.0 2.7–3.1 220–240V 1 ~ 50/60 3.7–4.3 3.8–4.5 220–240V 1 ~ 50/60 4.5–5.4 4.7–5.5...
  • Page 28 Electrical connection W5105H Heating alternative Main voltage Heating power Total power Recommended fuse Electric heated 200V 3 ~ 50/60 200V 3 ~ 50/60 220–240V 1 ~ 50/60 2.5–3.0 2.8–3.3 220–240V 1 ~ 50/60 4.4–5.2 4.6–5.5 220–240V 1 ~ 50/60 6.3–7.5 6.6–7.8...
  • Page 29 Electrical connection W5180H Heating alternative Main voltage Heating power Total power Recommended fuse Electric heated 200V 3 ~ 50/60 12.5 12.9 220–240V 3 ~ 50/60 9.1–10.8 9.4–11.1 220–240V 3 ~ 50/60 15.1–18.0 15.5–18.3 380–415V 3 ~ 50/60 9.0–10.8 9.4–11.1 380–415V 3 ~ 50/60 15.0–17.9 15.4–18.3...
  • Page 30: Machine Connection

    Electrical connection 7.3 Machine connection 7.3.1 Single-phase connection Connect the earth and other two wires as shown. 1NAC...
  • Page 31: Three-Phase Connection

    Electrical connection 7.3.2 Three-phase connection Connect the earth, neutral and phase wires as shown. 3N AC 3N AC...
  • Page 32: Functions For I/O-Cards

    Electrical connection 7.4 Functions for I/O-cards The electrical schematic can be one of the following: 7.4.1 External coin meter/Central payment (2A) The signal received from external coin meters must be a pulse between 300–3000 ms (500 ms is recommended) with a minimum pause of 300 ms (500 ms is recommended) between two pulses. ⑯...
  • Page 33: Central Payment (2B)

    Electrical connection 7.4.2 Central payment (2B) To start the machine from a central payment system, the payment system must transmit a start pulse to the machine. The start pulse can be either 230V or 24V. In order to receive a feedback signal once the machine has started, 230V or 24V must be connected to connection 19.
  • Page 34: Central Payment (2C)

    Electrical connection 7.4.3 Central payment (2C) The central payment or booking system shall transmit an active (high) signal to the machine once permission has been granted to start the machine. The signal must remain active (high) until the machine starts. A feedback signal will be present on connection 18 and remain active (high) whilst the machine door is closed but the program has not started.
  • Page 35: Outputs For Detergent Signals And Inputs For Pause Signals, "Empty" Signal And Price Reduction (2D)

    Electrical connection 7.4.4 Outputs for detergent signals and inputs for pause signals, "empty" signal and price reduction (2D) The figure shows standard function addressing for machines with the coin program package. By maintaining an active (high) signal on connection 5 ("Price red"), the price of the program can be reduced.
  • Page 36: Central Booking/Payment (2F)

    Electrical connection 7.4.5 Central booking/payment (2F) The central payment or booking system shall provide an active (high) signal to the machine once permission has been granted to start the machine. The signal must remain active (high) until the machine starts. A feedback signal will be present on connection 18 and remain active (high) whilst the program is running.
  • Page 37: Machines With I/O Module Type 3

    Electrical connection 7.4.6 Machines with I/O module type 3 By maintaining an active (high) signal on connection 3 "Price reduction”, the price of the program can be reduced. This function has a number of uses, including providing reductions during a specific period of the day.
  • Page 38: Steam Connection

    Steam connection 8 Steam connection Inlet pipes connected to the machine must be equipped with a manual shut-off valve to facilitate installation and servicing. The connection hose must be of type ISO/1307- 1983 or equivalent. Connection size at filter:DN 15 (BSP 1/2"). Demount the top panel (A).
  • Page 39 Steam connection Mount the hose with wires between steam valve and machine. Connect wires in the steam valve. Connect ground cable to the terminal ground connection. Connect the ”HEAT” cable connector to the ”HEAT” terminal on the I/O board. ”HEAT” fig.6604 Steam pressure required: •...
  • Page 40: Selection Of Language

    Selection of language 9 Selection of language When the installation is complete and the power is connected for the first time you will be forced to select language for the machine. Select language from the list on the display. This will be the language that all display messages, program names etc will be presented in. For more information about changing language and other functions please refer to the programming and configuration manual.
  • Page 41: Function Check

    Function check 10 Function check May only be carried out by qualified personnel. A function check must be made when the installation is finished and before the machine can be ready to be used. Open the manual water valves. Add detergent in the compartment for main wash and start a program. •...
  • Page 44 Electrolux Laundry Systems Sweden AB 341 80 Ljungby, Sweden www.electrolux.com/laundrysystems Share more of our thinking at www.electrolux.com...

This manual is also suitable for:

W5180hW5300hW5130hW5240hW565hW575h

Table of Contents