4.4.13 Canister and motor parameters

Canister motor parameters page
Machine (ES)
Need to calibrate the grinder when first using ,after
changing powders,canister or motor,。method of
calibration refer to the machine operation manual
Speed:
dosage:
Speed for calibration:
Sample dosage:
Motor test:
Calibration:
Filling powder in canister(there are raw material name
under the canister icon)
C1——Milk
C2——chocolate
Grinder ——Coffee Beans
Canister calibration method:
1)
Add powder to the corresponding canister,
shall not be less than 1/3 of canister
2)
Place an empty cup under the outlet of the
canister
3)
Click Sample dosage:Take the cup when
the powder is finished
4)
Put an empty cup on the electronic scale
and discharge to zero,then put it under the
outlet of the canister
Click Calibration : select "start" on the
5)
dialog box,when the powder box stops, the
cup is taken out and weighed on the
24