3.6 Water connector/drainage

3.6.1 Condition

Poor quality raw materials and water may damage the machine. Be sure to comply with measures to
prevent such hazards. Be sure to follow:
Water must be clean and pollution-free, chlorine content less than50 mg per liter.
Don't add reverse osmosis or other corrosive water to the coffee machine.
Carbonate hardness shall not exceed 5–6° DKH (German carbonate hardness) or 8.9–10.7° FKH
(FKH (French carbonate hardness).
Minimum carbonate hardness :5° DKH or 8.9° FKH.
Use new or machine-provided pipes (drinking water pipes / waste water pipes).
Must connect water sources in accordance with existing country regulations. If the machine is
connected to the newly installed water pipe, the water pipe and inlet pipe must be thoroughly flushed
to prevent stains from entering the machine.
The machine is directly connected to the external drinking water tank or waste water tank. The
corresponding level monitoring can be carried out.

3.6.2 Connection values

Water pressure
Water inlet temperature

3.7 Installation

3.7.1 Unpack the machine

Read the "place" and "power supply" chapters carefully before installation!
Pay attention to the accompanying installation instructions
Unpack the machine.
Check if the package contains accessories.
Remove attached accessories.

3.7.2 Automatic Debug Program

Machine run the debugging program automatically when first use. Which will describe all installation
items. Technician can start debugging programs at any time.

3.8 Disassembly and disposal

Coffee machines must be discarded properly in according to local regulations
► Please contact the Service Cooperation Agency
0.05 - 0.6 MPa (0.5 - 6 bar)
Minimum:
Maximum:
PH value: Between 6.5-7
10°C
30°C
14