Danger of electric shock! Directly hazardous situation, which may result in serious injury or death
due to electric shock.
Be sure to follow:
All power supply circuits must be shut down before touch or connect the terminals.
Power leakage protection devices must be protected by a fuse according to ampere value indicating
on the nameplate.
Power socket to equipment must be disconnected from the power grid.
Do not run the machine when power cable is damaged. Replace damaged power cable or socket by
professional technician immediately.
Suggest not to use extended power cable! If you need to use extended cables (minimum cross
section :1.5 mm² ), follow the power cable manufacturer's data (instructions) and local regulations
Make sure that the power cable does not trip the personnel. Do not drag the cable at the sharp or
corners, not clamp the cable or let it hang in the air. In addition, cables shall not be placed on high
temperature items ,shall be oil-proof and protect from corrosive cleaners.
Don't lift or pull the machine through the power cable. Do not pull the plug out of the socket by
pulling the power cable. Do not touch the power cable or plug with wet hands! Do not plug wet plugs
into sockets.
3.4.2 Power cable
Harm to client:
If the power cable is damaged or non-original, there is a risk of electric shock and fire! Use
original power cable.
Be sure to follow:
Purchase country-specific original power cables through service partners
Fixed-connected power cable shall be replaced by technician

3.4.2 Connecting data

Refer to nameplate on the machine.

3.5 Water connector

Water pump connect to the inlet of machine(G3 / 8 external thread).