Secure the loader arm valve with the loader valve lock
anytime you need to stop the machine with the loader
arms raised.
Keep nuts and bolts tight. Keep equipment in good
condition.
Never tamper with safety devices.
Keep the traction unit free of grass, leaves, or other debris
build-up. Clean up oil or fuel spillage. Allow the traction
unit to cool before storing.
Use extra care when handling fuels. They are flammable
and vapors are explosive.
– Use only an approved container.
– Never remove the fuel cap or add fuel when the
engine is running. Allow the engine to cool before
refueling. Do not smoke.
– Never refuel the traction unit indoors.
– Never store the traction unit or fuel container inside
where there is an open flame, such as near a water
heater or furnace.
– Never fill a container while it is inside a vehicle, trunk,
pick-up bed, or any surface other than the ground.
– Keep container nozzle in contact with the tank during
filling.
Stop and inspect the equipment if you strike an object.
Make any necessary repairs before restarting.
Use only genuine Toro replacement parts to ensure that
original standards are maintained.
Battery acid is poisonous and can cause burns. Avoid
contact with skin, eyes, and clothing. Protect your face,
eyes, and clothing when working with a battery.
Battery gases can explode. Keep cigarettes, sparks and
flames away from the battery.
Keep your body and hands away from pin hole leaks
or nozzles that eject high pressure hydraulic fluid. Use
cardboard or paper to find hydraulic leaks; never use
your hands. Hydraulic fluid escaping under pressure can
penetrate skin and cause injury requiring surgery within a
few hours by a qualified surgeon or gangrene may result.

Sound Pressure Level

Sound Pressure Level This unit has a sound pressure level at
the operator's ear of 93 dBA, which includes an Uncertainty
Value (K) of 1 dBA.
Sound pressure level was determined according to the
procedures outlined in EN 11201.

Sound Power

This unit has a guaranteed sound power level of 101 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
The sound power level was determined according to the
procedures outlined in ISO 6395.

Vibration Level

Measured vibration level for right hand = 1.5 m/s
Measured vibration level for left hand = 1.3 m/s
Uncertainty Value (K) = 0.8 m/s
Measured values were determined according to the procedures
outlined in EN ISO 20643.