Installation - Benchmark Alpha E-Tec Plus 28 Installation And Servicing Instruction

Wall mounted, fan assisted, room sealed, gas fired, high efficiency condensing combination boiler
Table of Contents

Advertisement

5

INSTALLATION

5.1
UNPACKING
1.
The boiler carton also contains the following:-
Connection kit (union bends, washers and valves)
Mounting bracket plus screws and wall plugs
Condensate discharge pipe
Literature pack and Wall template
A suitable Alpha flue system must be selected to use with the boiler.
Notes: a. All flues must be suitable for Alpha condensing boilers.
b. CD 750 mm and 1000 mm flue extensions are available, if required.
Damaged products must not be used.
2.
Unpack boiler and remove the loose items, packs and mounting bracket.
Note: The boiler can be stood in an upright position (only while the valves and union bends are not
fitted).
It is recommended that two persons lift the boiler.
4.2
CLEARANCES REQUIRED - Fig. 5.1
712 mm
268 mm
5.3
PREPARE THE WALL - Fig. 5.2
1.
Decide upon the position of the boiler taking into account the clearances required
for servicing and the flue terminal position.
2.
Tape the template to the wall (ensure it is level and the right
way up) and mark the position of the holes for the boiler
mounting bracket. If rear exit flue is used, mark the position of
the hole for the flue.
Side exit flue - Continue the horizontal centre line of the flue
3.
across the wall to the side wall, then along the side wall 135 mm
(ensure the lines are horizontal). This will give the position of the
centre of the hole for the flue.
4.
Cut the 110 mm diameter hole (or use a 107 mm core drill) in
the wall for the flue.
Notes: 1. Ensure the hole is horizontal.
2. For internal fitting of the flue, using the flue sealing
collar supplied, cut a 130 mm dia. flue hole using a 127
mm core drill.
5.
Drill the fixing holes (10 mm dia.) to accept the No.10 plugs
supplied. Using the screws supplied, fit the mounting bracket.
5 mm
Minimum
clearance
of 450 mm
from front
of boiler
Minimum clearances
235 mm - Can be reduced to
150 mm when using a
vertical flue
5 mm
440 mm
150 mm
Fig. 5.1
Rear exit hole
110 mm dia.
=
Alpha E-Tec Plus 28, 33 and 38 - Installation
Ensure line is level
=
143 mm
Fixing holes
if mounting
bracket used
Fixing holes
if wall jig used
Outline of
boiler
Template
Fig. 5.2
135 mm
Position of
110 mm hole
to be cut for
side exit flue
19