Technical Faults, Possible Causes And Remedies - Schaudt EBL 225 Instruction Manual

Electrobloc
Table of Contents

Advertisement

Starting up the system
SDT-0058-00EN
You cannot change from lead gel to lead acid batteries. Ask your dealer for
advice.
W
Danger of explosion from formation of detonating gas due to an incor-
rectly set battery selector switch, defective batteries, defective Electro-
bloc or an excessively high battery working temperature (more than
30 °C).
W
An incorrectly set battery selector switch damages the living area battery.
W
Disconnect the Electrobloc from the mains before adjusting the battery
selector switch.
The switching option provided by the battery selector switch ensures optimum
charging of the two different types of battery, lead acid and lead gel. The
switch must be set to the correct battery type: lead acid or lead gel.
Use a thin object (e.g. a ballpoint pen cartridge) to move the battery selector
switch.
Set lead gel battery: Set the battery selector switch to "Lead-Gel".
Set the lead acid battery: Set the battery selector switch to "Lead-Acid".
After changing batteries: Switch on the 12 V main switch on the control
and switch panel briefly to start up the consumers.
10

Technical faults, possible causes and remedies

If you are unable to solve a fault using the following tables, please contact our
customer service address.
If this is not possible, e.g. if you are abroad, you can have the Electrobloc
repaired at a specialist workshop.
Inexpert repairs invalidate the guarantee for the Electrobloc and Schaudt
GmbH takes no liability for any resulting damage.
Fault
Living area battery is not
charged during 230 V
operation (battery voltage
constantly below 13.3 V)
Living area battery is over-
charged during 230 V
operation (battery voltage
constantly above 14.5 V)
Starter battery is not
charged during 230 V
operation (battery voltage
constantly below 13.0 V)
Instruction Manual Electrobloc EBL 225
Possible cause
No mains voltage
Defective Electrobloc
Defective Electrobloc
No mains voltage
Defective Electrobloc
Situation: 14.06.2005
Remedy
Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Call customer service
Call customer service
Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Call customer service
9