Operating Faults - Schaudt EBL 101 D Instruction Manual

Hide thumbs

Advertisement

Instruction Manual EBL 101 D / EBL 101 C with OVP
Flat vehicle fuses
Self-resettingfuses
6
3.3
Faults
A fault in the power supply system is usually caused by a blown fuse.
The following functions are protected by self-resetting fuses:
Exit step
F
Sensor lines to the DT ... control and switch panel
F
If there is a fault with the step, it must not be operated for a period of 1 mi-
nute. The fuse resets automatically during this period.
For faults with the DT ... control and switch panel, the entire system must be
switched off from the battery cut-off and turned on again after about 1 mi-
nute.
Please contact our customer service department if you cannot rectify the
fault using the following table.
If this is not possible, e.g. if you are abroad, you can have the Electroblock
repaired at a specialist workshop. In this case, you must ensure that the
warranty is not invalidated by incorrect repairs being carried out. Schaudt
GmbH shall not accept any liability for damage resulting from such repairs.
Fault
Living area battery is not
charged during 230V ope-
g
g
ration (battery voltage
ti
(b tt
constantly below 13.3 V)
constantly below 13 3 V)
Living area battery is over-
charged during 230V ope-
ration (battery voltage
constantly above 14.5 V)
Starter battery is not char
Starter battery is not char- No mains voltage
ged during 230V opera-
tion (batter
tion (battery voltage con-
oltage con
stantly below 13.0 V)
Living area battery is not
g
charged during mobile
h
d d i
operation (battery voltage
operation (battery voltage
below 13.0 V)
The living area battery is
overcharged during mo-
bile operation (battery vol-
tage constantly above
14.3 V)
The refrigerator does not
work during mobile opera-
g
ti
tion
Possible cause
No mains voltage
p
lt
Defective Electroblock
Defective Electroblock
No mains voltage
Defective Electroblock
y
Defective alternator
bil
No voltage on D+ input
Defective Electroblock
Defective alternator
No power supply to the re-
p
frigerator
Defective Electroblock
Defective refrigerator
Date: 29.04.2010
Remedy
Switch on the automatic
fuse in the vehicle
Have the mains voltage
Have the mains voltage
checked
Call customer service
Call customer service
Switch on the automatic
Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Call customer service
Check the alternator
Check fuses and wiring
Call customer service
Check the alternator
Check fuse and wiring
Call customer service
Check the refrigerator
811.554 BA / EN