Starting up the system
3.3
Flat vehicle fuses
Polyswitch fuses
8110265 BA / EN
Instruction Manual for Electrobloc EBL 262-4
Fig. 1
Battery selector switch
Set the battery selector switch (fig. 1, pos. 1) to the correct position using
"
a thin object (such as a ballpoint pen):
Lead-gel battery: Set the battery selector switch to "Lead-gel".
F
Lead-acid battery: Set the battery selector switch to "Lead-acid".
F
Start up the system as described in section 3.1.
"

System faults

A fault in the power supply system is usually caused by a blown fuse.
Please contact our customer service department if you cannot rectify the
fault using the following table.
If this is not possible, e.g. if you are abroad, you can have the electrobloc
repaired at a specialist workshop. Please note that the warranty will become
void if incorrect repair work is carried out. Schaudt GmbH shall not accept
liability for any damages resulting from such repairs.
The following functions are protected by a polyswitch fuse:
12 V indicator
F
Battery 1
F
Output D+
F
If a fault occurs here, the electrobloc must be switched off for approx. 1 min.
and be disconnected from the 230 V mains. The polyswitch fuses reset au-
tomatically during this period.
Fault
Living area battery is not
g
y
charged during 230 V
h
d d i
230 V
operation (battery voltage
operation (battery voltage
constantly below 13.3 V)
y
)
Living area battery is
overcharged during 230 V
operation (battery voltage
constantly above 14.5 V)
Date: 08.07.2019
Possible cause
No mains voltage
g
Too many consumers are
switched on
Defective electrobloc
Defective electrobloc
1
Remedy
Switch on the automatic
circuit breaker in the
i
i b
k
i
h
vehicle; check the mains
vehicle; check the mains
voltage
Switch off consumers not
required
Contact the customer
service department
Contact the customer
service department
5