Automatic switch function
for AES/compressor
refrigerator
Mains charging of starter
battery
Awning light relay
Tank heater relay
Automatic disconnector
Cleaning
SDT-0058-00EN
6.2
Additional functions
7KLV UHOD\ VXSSOLHV WKH $(6FRPSUHVVRU UHIULJHUDWRU ZLWK SRZHU IURP WKH
VWDUWHU EDWWHU\ ZKHQ WKH YHKLFOH HQJLQH LV UXQQLQJ DQG WKH ' FRQQHFWLRQ LV
OLYH An AES/compressor refrigerator is powered by the living area battery
when the vehicle engine is switched off.
This feature provides an automatic float charge for the starter battery at up to
8 A if the 230 V mains is connected to the Electrobloc.
This relay controls the power supply of the awning light. The power supply to
the awning light is automatically interrupted as soon as the engine is running
and the D+ connection is live. The awning light can also be used if the 12 V
power supply is switched off.
This relay controls the waste water tank heater. The waste water tank heater
is activated at the control and switch panel.
6.3
Battery monitor
The battery monitor of the control and switch panel compares the voltage of
the living area battery to a reference voltage. As soon as the battery voltage
falls below 10.5 V, all 12 V consumers are switched off via main switch relays
1 and 2. Only the frost protection valve is still powered. The automatic discon-
nector is not triggered by short-term low voltage (less than 2 seconds),
caused by high current when switching on consumers.
If an overload or an insufficiently charged living area battery causes the volt-
age to fall so low that the automatic disconnector is triggered, any consumers
which are not essential should be switched off.
You may be able to switch on the 12 V power supply for a short time. To do
this, switch on the 12 V main switch on the control and switch panel.
However, if the battery voltage remains below 11.0 V, you cannot switch the
12 V power supply back on.
Fully charge up the living area battery as soon as possible.
7

Maintenance

The Electrobloc requires no maintenance.
Clean the Electrobloc with a soft, slightly damp cloth and mild detergent.
Never use spirit, thinners or similar substances.