Advertisement

 
Antenna connector
 
 
 
Frequency bands
UMTS with HSPA+
EGPRS
 
GPRS
 
GSM (CSD dial-in)
 
SMS (TX)
Electrical data
Power supply
Digital input
SCALANCE M874, M876
Operating Instructions, 02/2023, C79000-G8976-C331-12
M874-3
Quantity
1
Design
SMA socket (straight)
Impedance
50 Ω nominal
Antenna cable
Cable length < 30 m
UMTS
800 MHz, 850 MHz, 900 MHz, 1800 MHz, 1900
MHz, 2100 MHz
GSM
850 MHz, 900 MHz, 1800 MHz, 1900 MHz
Transmission speed
Properties
Multislot class 12, end device class B
Transmission speed
Properties
Multislot class 12, end device class B, coding
scheme 1 ... 4
Transmission speed
Properties
Radio Link Protocol (RLP) V.110, non-transparent
Transmission speed
up to 14.4 kbps
Properties
Text mode, SMSoverIP
Quantity
1
Design
Terminal block, 5-pin
Properties
Input voltage:
Maximum power consumption 8 W
Maximum cable length < 3 m
Quantity
1
Design
Terminal block, 2-pin
Properties
Rated voltage 24 VDC Safety Extra Low Voltage
(SELV)
For state "1": 10 to 30 VDC
For state "0": -30 to 3 VDC
Maximum input current 8 mA
Cables should be routed in pairs
Maximum cable length < 30 m
Inputs isolated from electronics.
Technical specifications
8.2 SCALANCE M874-3
HSDPA (downlink): up to 14.4 Mbps
HSUPA (uplink): up to 5.76 Mbps
Coding scheme downlink: CS 1 ... 4, MCS 1 ... 9
Coding scheme uplink: CS 1 ... 4, MCS 1 ... 9
Downlink: up to 237 kbps:
Uplink: up to 237 kbps:
Downlink: up to 85.6 kbps.
Uplink: up to 85.6 kbps.
12 to 24 VDC
min. 10.8 VDC, max. 28.8 VDC