Disposal
European Directive 2012/19/EU (WEEE)
The final disposal of the device must be done by specialized company.
Make sure the specialized company follows the classification of the material parts for the separation.
Observe the local regulations and dispose the device accordingly with the international rules for environment
protection.
Spare-parts request
When ordering spare parts, please quote their designation, position number in the cross section drawing and
rated data from the pump name plate (type, date and serial number).
Troubleshooting
WARNING: Turn off the power supply before performing any operations.
Do not allow the pump or motor to run when dry even for a short period.
Strictly follow the user instructions and if necessary contact an authorised service centre.
Problem
Probable Causes
The motor does not
1a. Unsuitable power
start
supply
1b. Incorrect electrical
connections
1c. Engine overload
protective device cuts in
1d. Blown or defective
fuses
1e. Shaft blocked
1f. If the above causes
have already been
checked the engine may
be malfunctioning
Possible Remedies
1a. Check that the mains frequency and voltage
correspond to the electrical characteristics shown on the
indicator plate
1b. Connect the power supply cable to the terminal board
correctly. Check that the thermal overload protection is
set correctly (see data on the engine indicator plate) and
make sure that the fuse board up line of the engine has
been properly connected
1c. Check the power supply and make sure that the
pump shaft is turning freely. Check that the thermal
overload protection has been set correctly (see engine
indicator plate)
1d. Replace the fuses, check the electric power supply
and points a) and c)
1e. Remove the cause of blockage as indicated in the
"Blocked pump" instruction booklet
1f. Repair or replace the engine by applying to an
authorised service center