Rated motor power
2900 1/min up to kW:
1450 1/min up to kW:
Sound Pressure dB(A) Max:
Starts/hour Max:
Maximum final pressure in the pump casing:
160 M (16 bar)
Maximum suction pressure: PN (Pa) - Hmax (Pa).
Operating conditions
Installation in well ventilated location protected from the weather, with a max ambient temperature of 40°C.
General provisions
The specialised technicians must carefully comply with all applicable standards and laws, including local
regulations of the country where the pump is sold.
The device has been built in conformity with the current safety laws. The improper use could damage people,
animals and objects.
The manufacturer declines any liability in the event of damage due to improper use or use under conditions
other than those indicated on the name-plate and in these instructions.
Follow the routine maintenance schedules and the promptly replace damaged parts, this will allows the
device to work in the best conditions.
Use only original spare parts provided from Flowtech.
Don't remove or change the labels placed on the device.
Do not start the device in case of defects or damaged parts.
Maintenance operations, requiring full or partial disassembly of the device, must be done only after
disconnection from the supply.
Safety devices
The device has an external case that prevents any contact with internal parts.
Residual Risks
The appliance designed for use when inline with the design and safety rules, doesn't have residual risks.
Information and Safety signals
For this kind of product there will not be any signals on the product.
Individual protection devices
During installation, starting and maintenance it is suggested to the authorized operators to consider the use
of individual protection devices suitable for described activities.
During ordinary and extraordinary maintenance interventions, safety gloves are required.
Signal individual protection device
Hand Protection - Gloves for protection against chemical, thermal and mechanical risks.
0.75
2.2
1.1
3
65
65
35
30
4
7.5
67
68
20
15
8
22
82
15
Need help?
Do you have a question about the flowboost F.V and is the answer not in the manual?