Embedded Communication Interface
Embedded Communication Protocol
Optional Communication protocol
Firmware Update Capabilities
Optional board UNO-DM-COM kit
Optional communication interface
Optional communication protocol
Optional board UNO-DM-PLUS Ethernet COM kit
Optional communication interface
Optional communication protocol ModBus TCP (SunSpec), ModBus RTU (SunSpec), Protocol Aurora
Acoustic noise emission level
Maximum operating altitude without derating
Classification of the degree of environmental pollution
Environmental protection rating
Overvoltage category according to IEC 62109-1
(check your sales channel for availability)
1. Refer to the document "String inverter – Product Manual appendix" available at www.abb.com/solarinverters to know the brand
and the model of the quick fit connector.
2. For UK G83/2 grid standard, maximum output current limited to 16A up to a maximum output power of 3600W and maximum
apparent power of 3600 VA.
3. The AC voltage range may vary depending on specific country grid standard
4. The Frequency range may vary depending on specific country grid standard. CE only for 50Hz.
5. As per IEEE 802.11 b/g/n standard
7. Plant Viewer for Mobile availble remotely only, not for local commissioning
8. Pacr = 4200 W @ 45°C/113°F
9. Further grid standard will be added, please refer to ABB Solar page for further details.
10. @ Pure sine wave condition.
Note. Features not specifically listed in the present data sheet are not included in the product
Communication
Commissioning tool
Monitoring
Environmental
Ambient temperature range
Relative humidity
Storage temperature
by external environment
Environmental category
Physical
Cooling
Dimension (H x W x D)
Weight
Mounting system
Safety
Isolation level
Marking
Safety class
Safety and EMC standard
Grid standard
(9)
UNO-DM-4.6
Wireless
ModBus TCP (SunSpec)
ModBus RTU (SunSpec) , Aurora Protocol
Web User Interface, Display, Aurora Manger Lite
Locally and remotely
Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile
ABB Ability™ for solar plants - Energy Viewer
RS485 (use with meter for dynamic control of the network
input), alarm relay / load manager, remote On / Off
ModBus RTU (SunSpec), protocol Aurora
Ethernet, RS485 (use with meter for dynamic control of the
network input), alarm relay / load manager, remote On / Off
-25...+60°C /-13...140°F with
derating above 40°C/104°F
(8)
0...100 % condensing
-45°C...+80°C / -49°F...176°F
50 dBA @ 1 m
2000 m / 6560 ft
External
IP 65
Natural
553mm x 418mm x 175mm / 21.8" x 16.5" x 6.9"
15 kg / 33 lb
Wall bracket
II (DC input) III (AC output)
Transformerless
CE, RCM
IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 4777.2,
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3,
EN 61000-6-4, EN 61000-3-11, EN 61000-3-12
CEI 0-21, DIN V VDE V
0126-1-1, VDE-AR-N 4105,
G59/3, RD 413, ITC-BT-40,
AS/NZS 4777.2, IEC 61727,
IEC 62116
- 31 -
3 - Characteristics
UNO-DM-5.0
(5)
-25...+60°C /-13...+ 140°F with
derating above 45°C/113°F
(10)
3
I
CEI 0-21, DIN V VDE V 0126-
1-1, VDE-AR-N 4105, G59/3,
RD 413, ITC-BT-40, AS/NZS
4777.2, C10/11, IEC 61727,
IEC 62116
,
(7)