ABB UNO-DM-2.0-TL-PLUS Manual page 149

Hide thumbs Also See for UNO-DM-2.0-TL-PLUS:
Table of Contents

Advertisement

INVERTER RUN
- PRODUCTION -
N.C.
Relay State: Switched
N.O.
GRID DISCONNECTION
- NO PRODUCTION -
N.C.
Relay State: Idle
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Idle
N.O.
DISCONNECTION
Yes
No
CAUSE IS STILL
PRESENT
INVERTER RUN
N.C.
Relay State: Idle
N.O.
ERROR OCCURENCY
ERROR MESSAGE
t=15s
N.C.
Relay State: Switched
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Idle
N.O.
ERROR
Yes
No
STILL
PRESENT
In the presence of W003, W004, W005, W006, W007 signalling, the alarm contact switches
to then reset itself at the end of the alarm signal. This means that during the absence of grid
voltage (display message "Missing Grid") the alarm contact remains in its resting position.
10. Alarm
This features will work only on inverter equipped with UNO-DM-COM KIT
(-X models) or UNO-DM-PLUS-COM ETHERNET KIT (-E models).
This section of the menu allows you to set the activation status of a relay
(available either as contact normally open – N.O. - and as a normally
closed contact -N.C.) and to configure customised alarm conditions.
This contact can be used, for example, to: activate a siren or a visual alarm,
control the disconnect device of an external transformer, or control an exter-
nal device.
Relay switching can be set in 9 different modes using the submenu Set
Alarm Type (For the "Alarm Conf.", "Al. Conf. Latch", "Al. Conf. Ext.",
"GoGo Rel(Auto)" and "GoGo Rel(Remote)" it is possible to configure
customised alarm conditions through the submenu Alarm Config:
• Production (display text "Production")
The relay is activated (status: switched) whenever the inverter connects
to the grid; as soon as the inverter is disconnected from the grid (for
whatever reason that caused disconnection), the relay is in its resting
position.
• Alarm with reset at the end of the alarm signalling process (display
text "Alarm"):
The relay is activated (status: switched) whenever an error (code Exxx)
or warnings related to grid parameters out of range (Warning – codes
W003, W004, W005, W006, W007) are present on the inverter. The
alarm returns to its resting position when the alarm signal ends, i.e. be-
fore the inverter checks the grid parameters after the alarm state. This
is because grid control state is not an alarm state but a state of normal
operation.
Alarms for which the relay is activated
E001
E002
E007
E010
E015
E016
E021
E022
E028
E029
E034
E035
E051
E053
E058
E065
E070
E074
E086
E087
W002
W003
W009
W011
W021
W022
W030
W036
W043
W046
W059
- 149 -
E003
E004
E005
E011
E012
E013
E017
E018
E019
E023
E025
E026
E030
E031
E032
E036
E037
E046
E054
E055
E056
E066
E067
E068
E077
E078
E080
E088
E089
W004
W005
W006
W015
W017
W018
W023
W024
W027
W037
W039
W040
W047
W048
W051
7 - Operation
E006
E014
E020
E027
E033
E050
E057
E069
E084
W007
W019
W029
W042
W058