INVERTER RUN
- PRODUCTION -
N.C.
Relay State: Switched
N.O.
GRID DISCONNECTION
- NO PRODUCTION -
N.C.
Relay State: Idle
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Idle
N.O.
DISCONNECTION
Yes
No
CAUSE IS STILL
PRESENT
INVERTER RUN
N.C.
Relay State: Idle
N.O.
ERROR OCCURENCY
ERROR MESSAGE
t=15s
N.C.
Relay State: Switched
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Idle
N.O.
ERROR
Yes
No
STILL
PRESENT
In the presence of W003, W004, W005, W006, W007 signalling, the alarm contact switches
to then reset itself at the end of the alarm signal. This means that during the absence of grid
voltage (display message "Missing Grid") the alarm contact remains in its resting position.
Local I/O Manager
In the Local I/O Manager sub-menu it's possible to enable the ma-
nagement of power flows in order to optimize self-consumption or
avoid feeding power to the grid (this features will work only on inverter
equipped with UNO-DM-COM KIT (-X models) or UNO-DM-PLUS-COM
ETHERNET KIT (-E models)).
This section of the menu allows you to set the activation status of a relay
(available either as contact normally open – N.O. - and as a normally
closed contact -N.C.) and to configure customised alarm conditions.
This contact can be used, for example, to: activate a siren or a visual alarm,
control the disconnect device of an external transformer, or control an external
device. A little description of the alarm type (e.g. "alarm lamp") is required.
Relay switching can be set in 9 different modes using the submenu Set
Alarm Type (For the "Alarm Conf.", "Al. Conf. Latch", "Al. Conf. Ext.",
"GoGo Rel(Auto)" and "GoGo Rel(Slave)" it is possible to configure cus-
tomised alarm conditions through the submenu Alarm Config:
• Alarm Production - display text "Alarm-Contact (Production)"
The relay is activated (status: switched) whenever the inverter connects to
the grid; as soon as the inverter is disconnected from the grid (for whatever
reason that caused disconnection), the relay is in its resting position.
• Alarm with reset at the end of the alarm signalling process - dis-
play text "Alarm-Contact (alarm ALL - no-latch)":
The relay is activated (status: switched) whenever an error (code Exxx)
or warnings related to grid parameters out of range (Warning – codes
W003, W004, W005, W006, W007) are present on the inverter. The alarm
returns to its resting position when the alarm signal ends, i.e. before the
inverter checks the grid parameters after the alarm state. This is because
grid control state is not an alarm state but a state of normal operation.
Alarms for which the relay is activated
E001
E002
E007
E010
E015
E016
E021
E022
E028
E029
E034
E035
E051
E053
E058
E065
E070
E074
E086
E087
W002
W003
W009
W011
W021
W022
W030
W036
W043
W046
W059
- 126 -
E003
E004
E005
E011
E012
E013
E017
E018
E019
E023
E025
E026
E030
E031
E032
E036
E037
E046
E054
E055
E056
E066
E067
E068
E077
E078
E080
E088
E089
W004
W005
W006
W015
W017
W018
W023
W024
W027
W037
W039
W040
W047
W048
W051
7 - Operation
E006
E014
E020
E027
E033
E050
E057
E069
E084
W007
W019
W029
W042
W058

Advertisement

Table of Contents
loading

Table of Contents