Vin > Vstart
N.C.
Relay State: Switched
N.O.
Vin < Vstart
N.C.
Relay State: Idle
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Idle
N.O.
Vin
Yes
No
IS STILL LESS THAN
Vstart
INVERTER RUN
N.C.
Relay State: Idle
N.O.
ERROR OCCURENCY
ERROR MESSAGE
t=15s
N.C.
Relay State: Switched
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Switched
N.O.
ERROR
Yes
No
STILL
PRESENT
• Crepuscolar - display text "Alarm-Contact (crepuscolar)":
The relay is activated (status: switched) as soon as the inverter input
voltage exceeds the activation voltage set.
The relay switch to rest position when the input voltage drops below 70%
of the activation voltage set.
This mode is useful for disconnecting any output transformers that could
have unnecessary consumption during the night.
• Alarm Latch - display text "Alarm-Contact (alarm ALL - latch)":
The relay is activated (status: switched) whenever an error (code Exxx)
or a warning (code Wxxx) is present (see the table below). When the in-
verter returns to the normal operating state and reconnects with the grid,
the contact returns to its position of rest.
Alarms for which the relay is activated
E001
E002
E007
E010
E015
E016
E021
E022
E028
E029
E034
E035
E051
E053
E058
E065
E070
E074
E086
E087
W002
W003
W009
W011
W021
W022
W030
W036
W043
W046
W059
If the alarm condition is persistent, the relay will remain activated
(status:switched)
- 128 -
E003
E004
E005
E011
E012
E013
E017
E018
E019
E023
E025
E026
E030
E031
E032
E036
E037
E046
E054
E055
E056
E066
E067
E068
E077
E078
E080
E088
E089
W004
W005
W006
W015
W017
W018
W023
W024
W027
W037
W039
W040
W047
W048
W051
7 - Operation
E006
E014
E020
E027
E033
E050
E057
E069
E084
W007
W019
W029
W042
W058