ABB UNO-DM-2.0-TL-PLUS Manual page 152

Hide thumbs Also See for UNO-DM-2.0-TL-PLUS:
Table of Contents

Advertisement

INVERTER RUN
N.C.
Relay State: Idle
N.O.
SELECTED
ERROR/WARNING
OCCURENCY
ERROR MESSAGE
t=15s
N.C.
Relay State: Switched
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Switched
N.O.
ERROR/WARNING
Yes
No
STILL
PRESENT
• Latch configurable alarm (display text "Al. Conf. Latch")
The relay is activated (status: switched) whenever an error (code Exxx)
or a warning (code Wxxx) is present from those selected from the list in
the dedicated submenu Alarm Config (see the table below). When the
inverter returns to the normal operating state and reconnects with the
grid.
Alarms for which the relay is activated
E001
E002
E007
E010
E015
E016
E022
E023
E029
E030
E036
E037
E054
E055
E066
E067
E077
E078
E088
E089
W002
W003
W009
W011
W021
W022
W029
W030
W042
W043
W058
W059
If the alarm condition is persistent, the relay will remain activated
(status:switched)
• Ext configurable alarm (display text "Al. Conf. Ext.")
In this mode, it is possible to configure the behaviour of the alarm relay
according to an external error table which can be setup with the Aurora
Manager LITE software. In the table it is possible to select the alarms
or warnings for which the alarm relay is activated (status: switched); for
each individual alarm it is also possible to select the "Latch" or "No Latch"
mode.
• Load Management (display text "Gogo rel. remote")
It allows you to enable the Load Management functionality with which the
relay is activated (status: switched) to a specific configurable power input
threshold. Once this mode has been selected, the parameters for which
the relay is activated have to be set (status: switched) on the dedicated
section of web user interface (see specific chapter).
- 152 -
E003
E004
E005
E011
E012
E013
E018
E019
E020
E025
E026
E027
E031
E032
E033
E046
E050
E051
E056
E057
E058
E068
E069
E070
E080
E084
E086
W004
W005
W006
W015
W017
W018
W023
W024
W025
W031
W037
W039
W046
W047
W048
7 - Operation
E006
E014
E021
E028
E034
E053
E065
E074
E087
W007
W019
W027
W040
W051

Advertisement