▪ Format: Paper (in the box of the indoor unit) + Digital files on Weather-dependent curve............25 http://www.daikineurope.com/support-and-manuals/product- 7.3.1 What is a weather-dependent curve? ......25 information/ 7.3.2 2-points curve ............. 26 ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
▪ A subset of the latest technical data is available on the regional Ethylene glycol is toxic. Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin WARNING Business Portal (authentication required). Due to the presence of glycol, corrosion of the system is Online tools possible.
Top panel User interface panel Switch box cover Front panel High voltage switch box cover Open 1 Remove the top panel. ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
"4.2.2 To lower the switch box on the indoor drain" [ 4 7] ▪ "4.3.2 To connect the drain hose to the ▪ When you need access to the high voltage switch box Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
3× 3 Slide the indoor unit into position. 4 Adjust the height of the leveling feet to compensate for floor irregularities. The maximum allowed deviation is 1°. ≤1° ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
7H will be generated (no heating or operation). See the installer reference guide for more information. See the recommended procedure as described in "8.2 Checklist commissioning" [ 4 30]. during Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Make sure both air purge valves (one on the magnetic filter and one on the backup heater) are open. All automatic air purge valves must remain open after commissioning. ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
▪ Normally closed valves (located indoors near the piping entry/exit hot water tank points) can prevent that all water from indoor piping is drained when the freeze protection valves open. Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
0.88 ±10% ▪ [3.A] Thermostat type ▪ [3.9] (read-only) Control Connections to the indoor unit Item Description Power supply (main) "6.3.1 To connect the main power supply" [ 4 12]. ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Wireless room thermostat ▪ Installation manual of the wireless room thermostat ▪ Addendum book optional equipment Wired room thermostat ▪ Installation manual of the wired room without multi-zoning base thermostat unit ▪ Addendum book optional equipment Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
2 kW 1N~ 230 V 9 A — (b)(c) 4 kW 1N~ 230 V 17 A 0.22 Ω (b)(c) 6 kW 1N~ 230 V 26 A 0.22 Ω 2 kW 3~ 230 V 5 A — 4 kW 3~ 230 V 10 A — 6 kW 3~ 230 V 15 A — ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
For more information, see the installer reference guide. Wires: 2×0.75 mm² Maximum running current: 100 mA 230 V AC supplied by PCB [2.D] Shut off valve unit" [ 4 5]): 1 Open the following (see "4.2.1 To open the indoor Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
X5M/6 and X5M/4; the negative polarity to X5M/5 and X5M/3. unit" [ 4 5]): 1 Open the following (see "4.2.1 To open the indoor 1 Top panel 2 User interface panel 3 Upper switch box cover ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
2 User interface panel required. 3 Upper switch box cover 2 Connect the space cooling/heating ON/OFF output cable to the appropriate terminals as shown in the illustration below. Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
2 User interface panel 3 Upper switch box cover 2 Connect the changeover to external heat source cable to the appropriate terminals as shown in the illustration below. ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Grid modes: Smart Grid contact Smart Grid operation mode Free running Forced off Recommended on Forced on The use of a Smart Grid pulse meter is not mandatory: Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Page 19
Screws for K1A and K2A Sticker to put on the high voltage wires Wires between the relays and X5M (AWG22 ORG) Wires between the relays and X10M (AWG18 RED) ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
This chapter describes what you have to do and know to configure the system after it is installed. High voltage Smart Grid contact 1 High voltage Smart Grid contact 2 Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
▪ Browse through the list of digits and change the selected digit. ▪ Move the cursor from left to right. ▪ Confirm the pin code and proceed. ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
This setting is read only. main LWT zone. Code Description [9.2.1] [E‑05] ▪ Integrated [E‑06] The backup heater will also be used for domestic hot water heating. [E‑07] Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
50°C, Glycol Filled system Daikin recommends NOT to disable the backup heater second step because it will have a big impact on the This setting gives the installer the possibility to indicate whether the required time for the unit to heat up the domestic hot water system is filled with glycol or water.
"7.2.5 Configuration zone" [ 4 24]. wizard: Main ▪ Enable leaving water temperature modulation and increase the maximum modulation [2.C]. Control Define how the operation of the unit is controlled. Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Because the slope of the curve depends on local circumstances such as climate and the insulation of the house, the curve can be adjusted by an installer or user. ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Possible actions on this screen X1, X2 Examples of outdoor ambient temperature Go through the temperatures. Change the temperature. Go to the next temperature. Confirm changes and proceed. Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
[3.5] Additional zone > the room frost protection is only possible if [C.2] Space Heating WD curve heating/cooling=On. Additional zone – Cooling [3.6] Additional zone > Cooling WD curve ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
▪ 2: 2 contacts 7.4.3 Information Dealer information The installer can fill in his contact number here. Code Description [8.3] Number that users can call in case of problems. Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Solar kit settings are shown but are NOT applicable for this unit. Settings shall NOT be used or changed. INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
The power supply voltage matches the voltage on the commissioning checklist is also available on the Daikin identification label of the unit. Business Portal (authentication required). There are NO loose connections or damaged electrical The general commissioning checklist is complementary to components in the switch box.
▪ Backup heater 2 test make sure the following is clear for the user: ▪ Pump test ▪ Fill in the installer setting table (in the operation manual) with the actual settings. ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Page 32
▪ Show the user what to do for the maintenance of the unit. ▪ Explain the user about energy saving tips as described in the operation manual. Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
10 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). 10.1 Piping diagram: Indoor unit...
Heat pump convector Heat pump convector English Translation Position in switch box (1) Main power connection (1) Main power connection English Translation Position in switch box Position in switch box Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Page 35
Shut-off valve Shut-off valve Smartgrid contacts Smart Grid contacts Smartgrid PV power pulse meter Smart Grid photovoltaic power pulse meter Switch box (7) Option PCBs (7) Option PCBs ETVH/X16S18+23EA6V+9W Installation manual Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Page 36
4 core communication A3P: X11M: 3-4-5-6 signal main & add: X2M: 3-4 Only for Human Comfort Interface 2 core 2×0.75 X5M: 11-12 A14P: P1-P2 user interface communication 4D133216A Installation manual ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02...
Page 40
4P644728-1 0000000T 4P644728-1 2021.02 Verantwortung für Energie und Umwelt...