Daikin ETVH16S18EA6V Installer's Reference Manual page 173

Hide thumbs Also See for ETVH16S18EA6V:
Table of Contents

Advertisement

EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644737-1 – 2021.02
#
Code
[4.5]
[F-0D]
Unit type
In this part of the menu it can be read out which type of unit is used:
#
Code
[4.6]
[E‑02]
Pump limitation
The pump speed limitation defines the maximum pump speed. In normal
conditions, the default setting should NOT be modified. The pump speed limitation
will be overruled when the flow rate is in the range of the minimum flow (error
7H).
In most cases, instead of using [9-0D]/[9-0E], you can prevent flow noises by
performing hydraulic balancing.
#
Code
[4.7]
[9-0D]
[4.8.1]
[9-0E]
[4.8.2]
[9-0D]
Possible values:
Description
2 Request: Pump operation based on request.
Example:
Using a room thermostat and
thermostat creates thermo ON/OFF condition.
Remark: NOT available in leaving water
temperature control.
a
b
c
d
c
b
e
b
c
a Space heating/cooling control
b Off
c On
d Heating demand (by external room thermostat
or room thermostat)
e Pump operation
Description
Unit type:
0 Reversible
1 Heating only
Description
Restriction: Only displayed when the bizone kit
(EKMIKPOA or EKMIKPHA) is NOT installed.
Pump limitation
Possible values: see below.
Restriction: Only displayed when the bizone kit
(EKMIKPOA or EKMIKPHA) is installed.
Pump limitation Main zone
Possible values: see below.
Restriction: Only displayed when the bizone kit
(EKMIKPOA or EKMIKPHA) is installed.
Pump limitation Additional zone
Possible values: see below.
10
Configuration
|
Installer reference guide
173