7
|
Unit installation

7.2.5 To open the indoor unit

Installer reference guide
68
3 2
Overview
a
c
e
b
d
a Top panel
b User interface panel
c Switch box cover
d Front panel
e High voltage switch box cover
Open
1 Remove the top panel.
T25
2 Remove the user interface panel. Open the hinges at the top and slide the top
panel upwards.
NOTICE
If you remove the user interface panel, also disconnect the cables from the back of
the user interface panel to prevent damage.
4
1
3
2
4
1
EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644737-1 – 2021.02

Advertisement