Daikin ETVH16S18EA6V Installer's Reference Manual page 190

Hide thumbs Also See for ETVH16S18EA6V:
Table of Contents

Advertisement

10
|
Configuration
Configuration wizard
Domestic hot water
Installer reference guide
190
After first power ON of the system, the user interface will guide you using the
configuration wizard. This way you can set the most important initial settings. This
way the unit will be able to run properly. Afterwards, more detailed settings can be
done via the menu structure if required.
To restart the configuration wizard, go to Installer
Configuration wizard [9.1].
Domestic hot water
The following setting determines if the system can prepare domestic hot water or
not, and which tank is used. This setting is read only.
#
Code
[9.2.1]
[E‑05]
[E‑06]
[E‑07]
(a)
Use the menu structure instead of the overview settings. Menu structure setting [9.2.1]
replaces the following 3 overview settings:
• [E-05]: Can the system prepare domestic hot water?
• [E-06]: Is a domestic hot water tank installed in the system?
• [E-07]: What kind of domestic hot water tank is installed?
DHW pump
#
Code
[9.2.2]
[D‑02]
See also:
"6.4.4 DHW pump for instant hot
"6.4.5 DHW pump for
DHW pump schedule
Program a schedule for the DHW pump (only for field supplied domestic hot
water pump for secondary return).
Program a domestic hot water pump schedule to determine when to turn on and
off the pump.
When turned on, the pump runs and makes sure hot water is instantly available at
the tap. To save energy, only turn on the pump during periods of the day when
instant hot water is necessary.
(a)
Integrated
(a)
The backup heater will also be used for
domestic hot water heating.
(a)
DHW pump:
0: No DHW pump: NOT installed
1: Instant hot water: Installed for instant
hot water when water is tapped. The user sets
the operation timing of the domestic hot water
pump using the schedule. Control of this pump
is possible with the user interface.
2: Disinfection: Installed for disinfection. It
runs when the disinfection function of the
domestic hot water tank is running. No further
settings are needed.
4
water" [
 52]
4
disinfection" [
 52]
settings >
Description
Description
EPRA14~18DAV3+W1 + ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644737-1 – 2021.02

Advertisement