Using The Product; Preparing For Measurement; Operating The Valve Positioners - TESTO 570 Series Instruction Manual

Digital manifold
Hide thumbs Also See for 570 Series:
Table of Contents

Advertisement

7 Using the product

2
Take a photo of the QR code of the
testo Smart App and press
[Menu/Enter]
-
The measurement menu is displayed.
7 Using the product
7.1

Preparing for measurement

7.1.1

Operating the valve positioners

With respect to the refrigerant path, the digital manifold behaves just like a
conventional four-way manifold: The passages are opened by opening the
valves. The applied pressure is measured with the valves closed and the valves
opened.
-
Open the valve: Turn valve positioner anticlockwise.
-
Close the valve: Turn valve positioner clockwise.
Valve positioner tightened too tightly.
Damage to the PTFE seal (1).
Mechanical deformation of the valve
piston (2) leading to the PTFE seal (1)
falling out.
Damage to the thread of the threaded
spindle (3) and the valve screw (4).
Broken valve knob (5).
Only tighten the valve positioner hand-tight.
Do not use any tools to tighten the valve
positioners.