2. Operation

2.1 Unpacking the Units

The Studio One 100 D package includes 1 unit fixture, power cord, power connector, colour frame, a Quick Start Guide and
an IR Remote.
We recommend that you keep the original packaging in case the item needs to be returned.

2.2 Cabling

The Studio One 100 D is built with chassis mount powerCon connectors for power input and through; chassis mount XLR 5-
pin connectors for DMX control data input and through.
The enclosure is ground bonded.
XLR 5-pin Cable:
Pin#
Function
1
Ground (Screen)
2
Data Minus
3
Data Plus
4
Spare Data Minus
5
Spare Data Plus
Power Cable:
International
North American
Colour Code
Colour Code
Green and Yellow
Green
Blue
White
Brown
Black
Important Notice: The use of an opto-splitter for DMX signal distribution is highly recommended when several fixtures are
not plugged into the same power source.

2.3 Mounting

The Studio One 100 D is built with a split yoke system for floor mounting and overhead hanging applications.
Secure the fixture with a safety bond when hung. A provision for a fixing hold is built into the fixture.

2.4 Optics

The Studio One 100 D is built with an optical lens that provides a fully homogenised beam angle of approximately ~ 18°.
Studio One 100 D User Manual
Connections
Earth (E)
Ground (Green)
Neutral (N)
Neutral (Silver)
Live (L)
Hot (Gold)