Riello UPS Netman208 Installation And User Manual page 94

Table of Contents

Advertisement

REGISTER
(1)
Number
Address
9
8
10
9
11
10
12
11
13
12
14
13
15
14
16
15
17
16
18
17
19
18
20
19
21
20
22
21
23
22
24
23
25
24
26
25
27
26
28
27
29
28
...
...
37
36
38
37
39
38
40
39
41
40
42
41
43
42
44
43
45
44
46
45
47
46
48
47
49
48
50
49
51
50
52
51
53
52
54
53
55
54
...
...
61
60
62
61
63
62
...
...
72
71
(1)
The register number n must be addressed n-1 in the data packet.
For single-phase systems, the value 0xFFFF is reported in the registers relating to L2 and L3.
Input voltage (Ph-N) V1
Input voltage (Ph-N) V2
Input voltage (Ph-N) V3
Input frequency
Bypass voltage (Ph-N) V1
Bypass voltage (Ph-N) V2
Bypass voltage (Ph-N) V3
Bypass frequency
Output voltage (Ph-N) V1
Output voltage (Ph-N) V2
Output voltage (Ph-N) V3
Load phase L1
Load phase L2
Load phase L3
Output frequency
Battery voltage
Charge%
Autonomy
Internal UPS temperature
MEASUREMENTS
- 94 -
UNIT
V
V
V
Hz/10
V
V
V
Hz/10
V
V
V
%
%
%
Hz/10
V/10
%
Minutes
°C

Hide quick links: