880 Export Series
Export 50 Hz (Two and Three Breaker Connections)
Voltage:
Max. Current Draw:
1-Pump System
2-Pump System
3-Pump System
Wattage:
1-Pump System
2-Pump System
3-Pump System
Frequency:
Number of Wires:
Single breaker is the factory default.
*** In this configuration, the heater will operate while all jets pumps are
running.
For 1 or 2-pump system, the heater terminal breaker will include con-
nections for heater, blower and lighting. The terminal breaker 2 will
include connections for pumps, circulation pump, CLEARRAY, stereo
(optional) and ozone (optional).
For 3-pump system, the heater terminal breaker will include con-
nections for heater and lighting. The terminal breaker 2 will include
connections for pumps, circulation pump, CLEARRAY, blower, stereo
(optional) and ozone (optional).
**** In this configuration, the heater will operate while all jets pumps are
running.
For 2-pump system, the heater terminal breaker will include connec-
tions for heater, blower and lighting. The terminal breaker 2 will include
connections for circulation pump, pump 1 and ozone (optional). The
terminal breaker 3 will include connections for pump 2, CLEARRAY and
stereo (optional).
For 3-pump system, the heater terminal breaker will include connec-
tions for heater and lighting. The terminal breaker 2 will include connec-
tions for pump 1, circulation pump, blower and ozone (optional). The
terminal breaker 3 will have connections for pump 2, pump 3, CLEAR-
RAY and stereo (optional).
18
Heater Terminal Breaker/
Terminal Breaker 2***
230 VAC
14A/10A
14A/17A
23A/26A
3.2kW/2.3kW
3.2kW/3.9kW
5.3kW/6.0kW
50 Hz
5
Heater Terminal Breaker/
Terminal Breaker 2/
Terminal Breaker 3****
230 VAC
N/A
14A/8A/9A
23A/10A/16A
N/A
3.2kW/1.8kW/2.1kW
5.3kW/2.3kW/3.7kW
50 Hz
5