3.3 Commissioning

3.3.1 Firmware update

Firmware update without
Startup Manager
Firmware update with
Startup Manager
HB160 | PPC | 67S-RRJ0 | en | 23-10
CAUTION!
Before commissioning the device must be brought to room tempera-
ture.
At condensation the device must be absolutely dry before connected
to power.
To avoid overheat during operation the device must not be laid open
to direct sun light.
After opening the control cabinet or desk, there are parts with pos-
sible dangerous voltage available.
For all signal connections only screened cables are permitted.
Signal cables must not be let within the same cable shaft as high
voltage cables.
CAUTION!
When changing the 'Regional Settings' , please note that only English
and German are supported, other languages can lead to a system crash.
To execute the firmware update an external keyboard and an USB stick (memory size
4GB) is necessary. The new image file for your Panel PC should be on the USB stick.
You will find the file and a detailed description of the firmware update on
www.yaskawa.eu.com in the Download Center under 67S-RRJ0-....
In the "Startup Manager", run the Firmware update of your Panel PCs via the [Info/
Update] button.
Deployment Panel PC
Commissioning > Firmware update