Deployment Panel Pc; Installation - YASKAWA 67S-PNJ0-EB Manual

Table of Contents

Advertisement

HMI
3

Deployment Panel PC

3.1 Installation

Overview
Installation cutting
Installation
HB160 | PPC | 67S-RRJ0 | en | 23-10
The Panel PC is suitable for the installation in operating tables and control cabinet fronts.
The installation happens via the back. The Panel PC is provided with a fixing technique
with not losable screws that allows an easy connection with a crosstip screwdriver. A fast
and easy device change is possible. It is also possible to install the Panel PC in a VESA
holder (VESA 75/100).
For the installation into a operating tableau and control cabinet fronts, the Panel PC
requires the following front panel cutting:
Panel PC
67S-RRJ0-...
The material thickness of the installation cut-out is 3 ... 12mm.
For the installation of the panel pivoted lever are integrated. For the installation, a crosstip
screwdriver is required.
1.
Push the Panel PC [3] from the front side into the front panel cutting [1] until it
touches the panel with the seal [2].
2.
Rotate the pivoted lever 90 degrees to the outside [4].
3.
Screw the screws with the crosstip screwdriver [5].
Deployment Panel PC
W x H in mm
547 x 367mm
Installation
23