3.2
Technical data
Tab.5
General
Main Eco Compact System
Gas council numbers
Nominal heat input — central heating —
Maximum rate
Nominal heat input 80/60C° — Minimum rate
Nominal heat output 80/60°C — central heat
ing — Maximum rate
Nominal heat output 80/60°C — central heat
ing — Factory setting
Nominal heat output 80/60°C — Minimum
rate
Nominal heat output 50/30°C — central heat
ing — Maximum rate
Nominal heat output 50/30°C — central heat
ing — Minimum rate
Tab.6
Central heating circuit specifications
Main Eco Compact System
Maximum pressure
Minimum pressure
Central heating temperature adjustment (±5°C)
Expansion vessel water capacity
Expansion vessel pre charge pressure
Maximum capacity of central heating system
Primary water content of boiler (unpressurised)
Tab.4
In IE the following Code of Practice apply:
Standard
Scope
IS 813
Domestic Gas Installations.
The following standards give valuable additional information:
BS 5546
Installation of hot water supplies for domestic purposes.
BS EN
Heating systems in buildings.
12828
BS EN
Heating systems in buildings — Calculation of load.
12831
BS EN
Installation & commissioning of water based heating sys
14336
tems.
BS 7074
Expansion vessels and ancillary equipment for sealed wa
ter systems.
BS 7593
Treatment of water in domestic hot water central heating
systems.
3.2.1
Technical information
Important
All data in these sections are nominal and subject to normal
production tolerances.
Net (Qn Hi)
kW
Gross (Qn Hs)
kW
Net (Qn Hi)
kW
Gross (Qn Hs)
kW
Pn
kW
Pn
kW
Pn
kW
Pnc
kW
Pn
kW
15
bar
3
bar
0.5
°C
25 / 80
litres
7.0
bar
1.0
litres
100
litres
2.5
15
41 467 30
41 467 31
15.5
17.2
4.64
5.15
15
15
4.5
16.2
4.9
18
3
0.5
25 / 80
7.0
1.0
100
2.5
3 Technical specifications
18
18.6
20.6
4.64
5.15
18
18
4.5
19.4
4.9
13