Terminal Guard; Flue/Chimney Deflector; Flue/Chimney Accessories; Transport - Main Eco Compact System 15 Installation And Service Manual

High efficiency wall hung condensing gas boiler
Table of Contents

Advertisement

5 Before installation
Fig.21

Terminal guard

1
Fig.22
Flue deflector
1
5.4

Transport

32
5.3.9
Terminal guard
1
ENSURE THAT NO PART OF THE WHITE OUTER CHIMNEY
DUCT IS VISIBLE.
When codes of practice dictate the use of terminal guards Multifit
accessory part no. 720627901 can be used
Important
This guard is not compatible with Flue Deflector referred to below.
There must be a clearance of at least 50mm between any part of the
terminal and the guard.
When ordering a terminal guard, quote the appliance name and model
number.
PN-0000460
The flue terminal guard should be positioned centrally over the terminal
and fixed as illustrated.
5.3.10

Flue/chimney deflector

1
Flue deflector
Push the flue deflector over the terminal end. It may point upwards as
shown, or up to 45° either way from vertical. Secure the deflector to the
terminal with screws provided.
PN-0000461
5.3.11

Flue/chimney accessories

See
For full details of Flue Accessories (elbows, extensions, clamps
etc.) refer to the Flue Installation Guide supplied in the literature
pack.
This product should be lifted and handled by two people. When lifting
always keep your back straight and wear protective equipment where
necessary. Carrying and lifting equipment should be used as required. e.g.
when install in a loft.