5.5
Securing the burner to the heat generator
Provide an adequate lifting system of the burner.
➤ Widen, if necessary, the insulating gasket holes (Fig. 7).
➤ Fix the flange 5) to the heat generator door 1)(Fig. 8) using
four screws 4) and if necessary the nuts 2) interposing the
insulating gasket 3) but keep unloosing one of the two upper
screws 4).
The burner can be fixed with the variable dimen-
sion A)(Fig. 9).
Anyway, make sure that the combustion head
WARNING
crosses completely the heat generator door thick-
ness.
20071805
Installation
➤ Put on the flange 5)(Fig. 8) the burner combustion head,
tighten the flange with the screws 6) and lock the loose
screw 4).
20073323
11
GB
D5012
20073324
Fig. 7
Fig. 8
Fig. 9