EXTREME SWITCHING 4450GTX-HT-PWR+ Installing

Virtual services platform
Hide thumbs Also See for 4450GTX-HT-PWR+:

Advertisement

Quick Links

Installing the Virtual Services Platform
4450GTX-HT-PWR+
Release 6.1
NN46251-304
Issue 07.02
December 2017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4450GTX-HT-PWR+ and is the answer not in the manual?

Questions and answers

Summary of Contents for EXTREME SWITCHING 4450GTX-HT-PWR+

  • Page 1 Installing the Virtual Services Platform 4450GTX-HT-PWR+ Release 6.1 NN46251-304 Issue 07.02 December 2017...
  • Page 2 © REPRESENT THAT YOU HAVE THE AUTHORITY TO BIND SUCH 2017, Extreme Networks, Inc. ENTITY TO THESE TERMS OF USE. IF YOU DO NOT HAVE SUCH All Rights Reserved. AUTHORITY, OR IF YOU DO NOT WISH TO ACCEPT THESE Notice TERMS OF USE, YOU MUST NOT ACCESS OR USE THE HOSTED SERVICE OR AUTHORIZE ANYONE TO ACCESS OR While reasonable efforts have been made to ensure that the...
  • Page 3 including any code and software unless expressly authorized by THE PERSONAL USE OF A CONSUMER OR OTHER USES IN Extreme Networks. Unauthorized reproduction, transmission, WHICH IT DOES NOT RECEIVE REMUNERATION TO: (I) ENCODE dissemination, storage, and or use without the express written VIDEO IN COMPLIANCE WITH THE AVC STANDARD (“AVC consent of Extreme Networks can be a criminal, as well as a civil VIDEO”) AND/OR (II) DECODE AVC VIDEO THAT WAS ENCODED...
  • Page 4 For additional information on Extreme Networks trademarks, please see: http://www.extremenetworks.com/company/legal/...
  • Page 5: Table Of Contents

    Contents Chapter 1: Preface........................7 ..........................7 Purpose ..........................7 Training ......................7 Providing Feedback to Us ..........................7 Getting Help .................... 8 Extreme Networks Documentation ................... 9 Subscribing to service notifications Chapter 2: New in this document..................10 Chapter 3: Hardware models....................11 ........................
  • Page 6 Contents ....................34 Port LED state indicators ......................35 Software restrictions Chapter 6: Translations of safety messages................ 36 December 2017 Installing the Virtual Services Platform 4450GTX-HT-PWR+...
  • Page 7: Chapter 1: Preface

    Chapter 1: Preface Purpose This guide provides information and instructions to install a Extreme Networks Virtual Services Platform 4450GTX-HT-PWR+ switch. Training Ongoing product training is available. For more information or to register, you can access the Web site at www.extremenetworks.com/education/. Providing Feedback to Us We are always striving to improve our documentation and help you work better, so we want to hear from you! We welcome all feedback but especially want to know about:...
  • Page 8: Extreme Networks Documentation

    Preface If you require assistance, contact Extreme Networks using one of the following methods: • GTAC (Global Technical Assistance Center) for Immediate Support - Phone: 1-800-998-2408 (toll-free in U.S. and Canada) or +1 408-579-2826. For the support phone number in your country, visit: www.extremenetworks.com/support/contact - Email: support@extremenetworks.com.
  • Page 9: Subscribing To Service Notifications

    Subscribing to service notifications Current Product Documentation www.extremenetworks.com/documentation/ Archived Documentation (for previous www.extremenetworks.com/support/documentation- archives/ versions and legacy products) Release Notes www.extremenetworks.com/support/release-notes Open Source Declarations Some software files have been licensed under certain open source licenses. More information is available at: www.extremenetworks.com/support/policies/software-licensing. Subscribing to service notifications Subscribe to receive an email notification for product and software release announcements, Vulnerability Notices, and Service Notifications.
  • Page 10: Chapter 2: New In This Document

    Chapter 2: New in this document The following sections detail what is new in Installing the Virtual Services Platform 4450GTX-HT- PWR+. Transceiver support VSP Operating System software now allows the use of transceivers and direct attach cables from any vendor, which means that the switch will bring up the port operationally when using any transceiver.
  • Page 11: Chapter 3: Hardware Models

    Chapter 3: Hardware models The following table describes the VSP 4450GTX-HT-PWR+ hardware. Table 1: Hardware VSP 4000 model Description Part number VSP 4450GTX-HT-PWR+ • 48 10/100/1000 BaseTX RJ-45 ports with EC4400A03-E6 802.3at PoE+ • two shared SFP ports • two SFP+ ports •...
  • Page 12: Platform Power Supplies

    Hardware models Platform power supplies The Virtual Services Platform 4450GTX-HT-PWR+ model supports two field-replaceable AC power supplies. One power supply is supplied with the chassis. You can install a redundant power supply to support load sharing or to provide power redundancy. The following table describes the Virtual Services Platform 4000 compatible AC power supplies and their part numbers (order codes).
  • Page 13 Supported optical devices Small Form Factor Pluggable (SFP) transceivers SFPs are hot-swappable input and output enhancement components designed for use with Extreme Networks products to allow gigabit Ethernet ports to link with other gigabit Ethernet ports over various media types. You can use various SFP (1Gb/s) and SFP+ (10Gb/s) to attain different line rates and reaches.
  • Page 14: Chapter 4: Preinstallation Checklist

    Chapter 4: Preinstallation checklist Before you install the VSP 4450GTX-HT-PWR+, make sure that you complete the tasks in the preinstallation checklist. Task Description Review the technical specification for For the physical, electrical, and environmental the switch. Make sure that the area specifications, see Technical specifications where you install the switch and where...
  • Page 15 Task Description in the area. The ground path must be permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrode. December 2017 Installing the Virtual Services Platform 4450GTX-HT-PWR+...
  • Page 16: Chapter 5: Installing The Vsp 4450Gtx-Ht-Pwr

    Chapter 5: Installing the VSP 4450GTX-HT- PWR+ Installation checklist Use this checklist to install the VSP 4450GTX-HT-PWR+. Task Description Install the VSP 4450GTX-HT-PWR+. You can install the switch in two ways: • Installing the Virtual Services Platform 4000 on a table or shelf on page 21 •...
  • Page 17: Electrostatic Discharge

    Electrostatic discharge Figure 1: VSP 4450GTX-HT-PWR+ 1. USB 2.0 port Note: The VSP 4450GTX-HT-PWR+ model does not require a USB device in the USB port for normal operation. The USB port can be used for file transfer of configs and logs using a USB drive. 2.
  • Page 18: Preventing Electrostatic Damage In New Cable Installations

    Installing the VSP 4450GTX-HT-PWR+ • Avoid contact between equipment and clothing. The wrist or ankle strap protects only the equipment from ESD voltages on the body; ESD voltages on clothing can still cause damage. • Avoid touching any connector pins. •...
  • Page 19: Environmental Requirements

    Environmental requirements Warning: To avoid bodily injury from hazardous electrical shock and current, never remove the top of the device. No user-serviceable components are inside. Table 3: Physical specifications Specifications 4450GTX-HT-PWR+ Height 8.8 cm. – 2RU Width 44 cm. Depth 36.8 cm.
  • Page 20: Airflow Direction

    Installing the VSP 4450GTX-HT-PWR+ Environmental requirement Virtual Services Platform 4000 models • At least 2 inches (5.08 centimeters) of clearance on each side of the switch unit for ventilation. • Adequate clearance at the front and rear of the switch for access to cables.
  • Page 21: Installing The Virtual Services Platform 4000 On A Table Or Shelf

    Installing the Virtual Services Platform 4000 on a table or shelf b. Virtual Services Platform 4000 Series Regulatory Guide c. Virtual Services Platform 4450GTX-HT-PWR+ Quick Install Guide d. The China RoHS paper Installing the Virtual Services Platform 4000 on a table or shelf You can install a single VSP 4000 switch on any flat surface.
  • Page 22: Installing The Virtual Services Platform 4000 In An Equipment Rack

    Installing the VSP 4450GTX-HT-PWR+ Installing the Virtual Services Platform 4000 in an equipment rack To install the VSP 4000 switch in an equipment rack, perform this procedure. Prerequisites for installing the VSP 4000 in an equipment rack: • Ensure that you have a space of 1.75 inches (4.45 centimeters) in height for each switch in an EIA or IEC-standard 19-inch (48.2-centimeter) equipment rack.
  • Page 23: Cable Requirements For The Virtual Services Platform 4000 Series

    Cable requirements for the Virtual Services Platform 4000 Series 3. Insert and tighten the rack-mount screws. Cable requirements for the Virtual Services Platform 4000 Series The following table describes the cables required for an VSP 4450GTX-HT-PWR+ switch. Table 5: Switch cable requirements Required Cable Description 10/100/1000Base TX Ports...
  • Page 24: Installation And Removal Of Small Form Factor Pluggable (Sfp) Transceivers

    Installing the VSP 4450GTX-HT-PWR+ Required Cable Description 100BaseFX Ports The interconnect cabling must conform to 50/125 or 62.5/125 micron multimode fiber-optic cabling for distances up to 3 kilometers. Console Port Varies depending on the user device. The VSP 4000 has an RJ-45 female connector, so a serial cable with RJ-45 connectors, or a serial cable with a DB-9 female connector on one end and an RJ-45 on the other is appropriate.
  • Page 25: Rj-45 Connector Pin Assignments

    RJ-45 connector pin assignments 3. Slide the transceiver from the module slot. 4. If the transceiver does not slide easily from the module slot, use a gentle side-to-side rocking motion while firmly pulling the transceiver from the slot. 5. Attach a dust cover over the fiber-optic bores and store the transceiver in a safe place until you need it.
  • Page 26: Installing The Virtual Services Platform 4000 Power Supply

    Installing the VSP 4450GTX-HT-PWR+ Connector Pin Number Signal Not used Request to send (not used) Not used Ring indicator (not used) Table 7: RJ–45 Console port pin assignments Connector Pin Number Signal Ready to send (RTS) — optional Data terminal ready (DTR) — optional, can swap or link with pin 8 Transmit data (TXD) —...
  • Page 27: Virtual Services Platform Power Supply Power Specification

    Installing the Virtual Services Platform 4000 power supply Note: The switch chassis can prevent an incorrect installation of a power supply. If you insert a power supply upside down, it will not fully insert and the thumb screws will not engage.
  • Page 28 Installing the VSP 4450GTX-HT-PWR+ Connector The 1000W AC power supply uses an IEC 60320 C16 AC power cord connector. The AC power cord is in close proximity to the hot air exhaust, and supports high operating temperatures. Figure 4: IEC 60320 C16 connector Power over Ethernet Plus specifications Table 8: VSP 4450GTX-HT-PWR+ model 0°C to 50°C...
  • Page 29: Connect Ac Power

    Connect AC power 4450GTX-HT-PWR+ Input Voltage (rms): 100 to 240VAC at 50 to 60 Hz Power Consumption: • Without PoE+ - Typical: 100W - Maximum: 145W • With PoE+ - Typical power utilization depends on the number of ports using PoE+. - Maximum: 553.4W Thermal Rating: 341.2 BTU/Hr typical and 494.8 BTU/Hr maximum...
  • Page 30: Connect Power To The Front Panel

    Installing the VSP 4450GTX-HT-PWR+ Country and Plug Specification Specifications Typical Plug United Kingdom: • 240VAC • BS1363 male plug with fuse • 50 Hz • Harmonized cord • Single phase Australia: • 240VAC • AS3112-1981 male plug • 50 Hz •...
  • Page 31 Connect AC power Warning: Disconnecting the AC power cord is the only way to turn off AC power to the VSP 4000. Always connect the AC power cord in a quickly and safely accessible location in case of an emergency. For a translation of this statement, see Translations of safety messages page 36.
  • Page 32: Led State Definitions

    Installing the VSP 4450GTX-HT-PWR+ umount: can't open '/proc/mounts' sed: /proc/mounts: No such file or directory sed: /proc/mounts: No such file or directory sed: /proc/mounts: No such file or directory Deconfiguring network interfaces... done. Stopping syslogd/klogd: no syslogd found; none killed Sending all processes the TERM signal...
  • Page 33: Switch Led State Indicators

    LED state definitions 1. USB 2.0 port 2. Switch LEDs 3. 10/100/1000 Base TX RJ-45 ports with PoE+ (LEDs above ports) 4. 100/1000 Mbps SFP transciever modules 5. 1/10G SFP + ports 6. Console Port Warning: Fiber optic equipment can emit laser or infrared light that can injure your eyes. Never look into an optical fiber or connector port.
  • Page 34 Installing the VSP 4450GTX-HT-PWR+ Label Color and Status Description Green (solid) The switch is connected to a redundant power supply unit (RPS) or a secondary external power supply, and is operating normally. Green (blinking) The switch is connected to a secondary power supply, but the power input is disconnected.
  • Page 35 Software restrictions Label Color and Status Description Local/remote fault. Table 15: SFP/SFP+ transceiver Port LED state indicators Label Color and Status Description In Use Green, Blink Not applicable. Green, Steady The SFP/SFP+ port and the transmit port are active. Amber, Blink Not applicable.
  • Page 36 Chapter 6: Translations of safety messages Caution: When you mount this device in a rack, do not stack units directly on top of one another. You must secure each unit to the rack with appropriate mounting brackets. Mounting brackets cannot support multiple units. Important: Achtung: Wenn diese Einheit in einem Rack montiert wird, muß...
  • Page 37 Caution: If you are not installing a module in the slot, be sure to keep the metal cover plate in place over the slot. Removing the cover plate impedes airflow and proper cooling of the unit. Important: Achtung: Wenn Sie kein Modul im Schacht verwenden, muß die Metallabdeckung über dem Schacht montiert sein.
  • Page 38 Translations of safety messages Warning: Disconnecting the AC power cord is the only way to turn off AC power to this device. Always connect the AC power cord in a quickly and safely accessible location in case of an emergency. Important: Warnung: Das Gerät kann nur durch Ziehen des Netzsteckers ausgeschaltet werden.
  • Page 39 Verwenden Sie nur Netzkabel mit Schutzerdung. Ohne ordnungsgemäße Schutzerdung besteht für Personen, die den Switch berühren, die Gefahr eines elektrischen Schlages. Eine nichtvorhandene Schutzerdung kann zu sehr starken Abstrahlungen führen. Danger: N'utilisez que des cordons d'alimentation équipés de trajet de mise à la terre. Sans mise à la terre adaptée, vous risquez de recevoir une décharge électrique en touchant le commutateur.
  • Page 40 Translations of safety messages Important: 警告: 系 Extreme 池不支持 更 , 只有授 人 才能 行拆卸和更 。 如果您需要更 池, Networks 技 支持部 求帮助。 Important: Advertencia: La batería de litio no puede sustituirse en campo. La extracción y sustitución debe ser realizada exclusivamente por personal autorizado.

This manual is also suitable for:

Vsp 4000Vsp 4450gtx-ht-pwr+

Table of Contents