Chapter 2: New in this document.................. 10 Chapter 3: Preinstallation Checklist.................. 11 Chapter 4: Installation Preparation.................. 13 ........................ 13 Switch Models ............ 14 Universal Serial Bus Ports on the ERS 3600 Series ................ 14 Electrostatic Discharge Prevention ...................... 15 Technical Specifications ....................... 17 Power Specifications .................... 18...
Page 4
CCC EMC Statement — China ..................... 49 Battery Warning — Taiwan ........................ 49 Battery Notice .................. 50 Restriction of Hazardous Substances ...................... 50 Hazardous Substances ........ 50 European Waste Electrical and Electronic Equipment (WEEE) Notice ........................... 51 Safety August 2019 Installing Ethernet Routing Switch 3600 Series...
Extreme Networks publications. Purpose This document provides the information and procedures required to install the hardware, software, cabling, and power for the Ethernet Routing Switch 3600 Series. Unless otherwise indicated, this information applies to: • ERS 3626GTS •...
Page 6
Ellipses ( … ) An ellipsis ( … ) indicates that you repeat the last element of the command as needed. For example, if the command syntax is ethernet/2/1 [ <parameter> Table continues… August 2019 Installing Ethernet Routing Switch 3600 Series...
You can subscribe to email notifications for product and software release announcements, Vulnerability Notices, and Service Notifications. 1. Go to www.extremenetworks.com/support/service-notification-form. 2. Complete the form with your information (all fields are required). August 2019 Installing Ethernet Routing Switch 3600 Series...
• Email us at documentation@extremenetworks.com. Please provide the publication title, part number, and as much detail as possible, including the topic heading and page number if applicable, as well as your suggestions for improvement. August 2019 Installing Ethernet Routing Switch 3600 Series...
The following sections detail what is new in this document. Regulatory and Compliance Information This document is updated with the Regulatory and Compliance information from Regulatory Reference for Ethernet Routing Switch 3600 Series, which is now obsolete. For more information, Regulatory and Compliance Information on page 46.
Chapter 3: Preinstallation Checklist Before you install the ERS 3600 Series, make sure that you complete the tasks in the preinstallation checklist. Task Description Review the technical specification for For the physical, electrical, and the switch. Make sure that the area...
Page 12
Preinstallation Checklist Task Description path must be permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrode. Installing ERS 3600 in an equipment rack on page 25. August 2019 Installing Ethernet Routing Switch 3600 Series...
Chapter 4: Installation Preparation Switch Models The following table describes the ERS 3600 Series models. All switch models support autopolarity. Model Key features Part number ERS 3626GTS • 24 10/100/1000 ports AL3600?05-E6 • Two shared SFP ports • Two 1/10 Gigabit SFP+ ports operating in dual mode as uplink ports •...
Universal Serial Bus Ports on the ERS 3600 Series The ERS 3600 Series includes a USB Type A port on the front panel adjacent to the console port. The USB Type A port enables switch administrators to perform tasks that were previously completed through TFTP with a commonly available USB Mass Storage Device (also know as a flash drive or thumb drive).
To avoid bodily injury from hazardous electrical shock and current, never remove the top of the device. No user-serviceable components are inside. Table 3: Physical specifications Switch Specification Height ERS 3650GTS-PWR+, ERS 1U or 44.5 mm (1.75 inches) 3650GTS-PWR+, ERS 3626GTS, ERS 3626GTS-PWR+ Table continues… August 2019 Installing Ethernet Routing Switch 3600 Series...
Page 16
95% RH non-condensing Storage Humidity 95% RH non-condensing Maximum Operating Altitude 10,000 ft Storage Altitude 10,000 ft Acoustic Noise (db) ERS 3650GTS - 40.7dB@25C, 47.4dB@50C ERS 3650GTS-PWR+ - 46.8dB@25C, 54.6dB@50C Table continues… August 2019 Installing Ethernet Routing Switch 3600 Series...
• No nearby sources of severe electromagnetic noise • No nearby heat sources such as hot air vents or direct sunlight Power Specifications This section provides the following specifications for ERS 3600 Series. Table 6: AC power specifications Model Power supply...
914.1W 100V-240VAC 48 Ports at 720W AC Power Cord Specifications The following section outlines the AC power cord specifications for various countries. Ensure that you use the correct cord for your location. August 2019 Installing Ethernet Routing Switch 3600 Series...
AC power cords are not packaged with the switch. Ensure you order the correct power cord for your region. Order Code Description Region AA0020062E6 POWER CORD 3.05M IEC C13 TO NEMA 5-15P North America Table continues… August 2019 Installing Ethernet Routing Switch 3600 Series...
POWER CORD 2.5M IEC C13 TO SI-32 Israel Verify the Package Contents Note: AC power cords are not packaged with the switch. Ensure you order the correct power cord for your region. August 2019 Installing Ethernet Routing Switch 3600 Series...
Use only power cords with a grounding path. Without a proper ground, a person who touches the switch is in danger of receiving an electrical shock. A switch without a proper grounding path can result in excessive emissions. August 2019 Installing Ethernet Routing Switch 3600 Series...
Page 22
The only way to turn off the switch is to disconnect the power. Always connect the AC power cord in a location that can be reached quickly and safely in case of an emergency. August 2019 Installing Ethernet Routing Switch 3600 Series...
Ambient temperature when low power mode is used must be 30 degrees Celsius (86 F) or lower. About this task The following procedure provides instructions for installing the switch on a table or shelf. Procedure 1. Insert the rubber feet at the bottom of the switch. August 2019 Installing Ethernet Routing Switch 3600 Series...
Page 24
Installing the Switch 2. Set the switch on a table or shelf. August 2019 Installing Ethernet Routing Switch 3600 Series...
Procedure 1. Ensure power is disconnected from the switch. 2. Attach a bracket to each side of the switch with the included screws. August 2019 Installing Ethernet Routing Switch 3600 Series...
With SFP+ 10Gb stacking cables, the stack bandwidth is 2 ports x 10Gbps/port x 2 directions = 40 Gbps. Standalone Arrangement Any one switch can operate in a standalone configuration. You can add more switches as your traffic increases. August 2019 Installing Ethernet Routing Switch 3600 Series...
During the initial installation of the stack, the software automatically determines the physical order of all units in the stack according to the position of the base unit within the stack. Thereafter, the August 2019 Installing Ethernet Routing Switch 3600 Series...
Unit 2. The stack is wired downward through the units and the system continues to number in this manner throughout the stack. In this configuration, the base unit discovers the stack in a cascade down (stack down) direction. August 2019 Installing Ethernet Routing Switch 3600 Series...
In a cascade up (stack up) configuration, the base unit is physically located as the top unit in the stack. The cable connected to the Cascade Down connector of the base unit terminates in the August 2019 Installing Ethernet Routing Switch 3600 Series...
Redundant Cascade Stacking The ERS 3600 Series allow a stack of up to eight units in a stack. If any single unit fails or if a cable is accidently disconnected, other units in the stack remain operational without interruption.
Description 10/100/1GBase-T Ports The interconnect cabling must conform to the Cat5e, Cat6, or Cat6e specification of the Commercial Building Telecommunications Cabling Standard, ANSI/TIA/EIA 568-B fitted with an RJ-45 Module Jack. Table continues… August 2019 Installing Ethernet Routing Switch 3600 Series...
5. Remove the dust cover from the transceiver optical bores. Job Aid The following graphic shows an SFP transceiver. The figure does not represent a specific product. August 2019 Installing Ethernet Routing Switch 3600 Series...
For more information about transceiver use and designation, see Extreme Networks Pluggable Transceivers Installation Guide. Important: The attainable cable length can vary depending on the quality of the fiber-optic cable used. August 2019 Installing Ethernet Routing Switch 3600 Series...
Checking Status LEDs to Verify Switch Installation Perform this procedure to verify the hardware installation and operation of the unit. The status LEDs on the front of the unit indicate the installation and operational status of the hardware. August 2019 Installing Ethernet Routing Switch 3600 Series...
Page 35
1. Locate the status LEDs on the front of the unit; see the following figure. Figure 5: Status LEDs 2. Verify the status and operating mode of the unit. For status LED state descriptions, see the following table. August 2019 Installing Ethernet Routing Switch 3600 Series...
Page 36
LNK/ACT Green/steady This link is operating normally. Green/blinking There is activity on the port. Green/slow blinking The port has been disabled by the software. Indicates that the link has been lost. August 2019 Installing Ethernet Routing Switch 3600 Series...
• Terminal with AC power cord and keyboard • Serial cable — a DB-9 to RJ-45 adapter or other suitable console cables can be used – the maximum length of a console cable is 25 feet (8.3 meters) August 2019 Installing Ethernet Routing Switch 3600 Series...
Any terminal or PC with an appropriate terminal emulator can be used as the management station. The following table lists the parameters that must be used with any terminal emulation software used to connect to the switch. August 2019 Installing Ethernet Routing Switch 3600 Series...
• Ensure the terminal from which you ping the switch is on the same network as the switch. Procedure Ping the 3600 Series switch from a terminal or workstation that is on the same network. If the network device sends a ping reply, a message indicates that the specified IP address is alive and can communicate with other devices.
Optional (can be swapped or linked with pin USB Port The USB port is a Standard Type-A female USB 2.1 port. The switch provides USB host functionality and can support USB flash drives. August 2019 Installing Ethernet Routing Switch 3600 Series...
Se il dispositivo viene installato in un rack, non impilare le unità direttamente una sull’altra. Ogni unità deve essere fissata al rack con le staffe di montaggio appropriate. Le staffe di montaggio non sono state progettate per supportare più unità. August 2019 Installing Ethernet Routing Switch 3600 Series...
Page 43
Attenzione: Se nello slot non vengono installati moduli, assicurarsi di mantenere la piastra di copertura metallica in sede sopra lo slot. La rimozione della piastra impedisce la ventilazione e il corretto raffreddamento dell’unità. August 2019 Installing Ethernet Routing Switch 3600 Series...
Page 44
N’utilisez que des cordons d’alimentation équipés de trajet de mise à la terre. Sans mise à la terre adaptée, vous risquez de recevoir une décharge électrique en touchant le commutateur. Par ailleurs, l’absence de trajet de mise à la terre peut générer des émissions excessives. August 2019 Installing Ethernet Routing Switch 3600 Series...
Page 45
Senza un’adeguata messa a terra, chiunque tocchi lo switch corre il rischio di ricevere una scossa elettrica. L’assenza di un percorso per la messa a terra verso lo switch può comportare un eccesso di emissioni. August 2019 Installing Ethernet Routing Switch 3600 Series...
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. August 2019 Installing Ethernet Routing Switch 3600 Series...
CSA-C22.2 No. 60950-1, EN 60950-1, EN 60825-1, EN 60825-2, IEC 60950-1, 2006/95/EC. Produktsicherheit Dieses Produkt entspricht den folgenden Richtlinien: UL 60950-1, FDA 21 CFR 1040.10 and 1040.11, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, EN 60825-1, EN 60825-2, IEC 60950-1, 2006/95/EC. Korea EMC Statement August 2019 Installing Ethernet Routing Switch 3600 Series...
BSMI EMC Statement — Taiwan This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. August 2019 Installing Ethernet Routing Switch 3600 Series...
Il y a risque d’explosion si la pile est remplacée par un type de pile incorrect. Éliminez les piles usées en conformité aux règlements locaux d'élimination des piles. August 2019 Installing Ethernet Routing Switch 3600 Series...
4. It is the users’ responsibility to utilize the available collection system to ensure WEEE is properly treated. For information about the available collection system, please contact Extreme Networks Customer Support at +353 61 705500 (Ireland). August 2019 Installing Ethernet Routing Switch 3600 Series...