The screen displays "PLATEN NOT
LATCHED. CALL SERVICE-LATCH. IS
AN OBJECT STUCK UNDER THE
PLATEN? IF NO, COOK FLAT ITEMS
ONLY."
Cause: An item may be under platen,
preventing it from latching.
Remedy: Remove the item and try again.
Cause: The pneumatic system is faulty.
Remedy: Call an authorized service technician.
Cause: The latch switch is faulty.
Remedy: Call an authorized service technician.
Cause: The latch solenoid is faulty.
Remedy: Call an authorized service technician.
Grill Cleaning
Startup & Cooking
The display reads "UPPER PLATEN
STUCK. CALL SERVICE-LATCH. IF
THE PLATEN IS OPEN, COOK FLAT
ITEMS ONLY."
Cause: The arm bearings are dirty.
Remedy: Call an authorized service technician.
Cause: The air cylinder is faulty.
Remedy: Call an authorized service technician.
Cause: Plugged air lines to cylinders.
Remedy: Call an authorized service technician.