Full Gauge Controls EVOLUTION TC-970E Log+ECO Manual page 7

Digital freezing controller

Advertisement

Fun
[,F89]
AUX output mode
[,F90]
Time to turn on the AUX output if [,F89] = 5 (Monday to friday)
[,F91]
Time to turn off the AUX output if [,F89] = 5 (Monday to friday)
Time to turn on the AUX output if [,F89]= 5 (Saturday)
[,F92]
[,F93]
Time to turn off AUX output if [,F89] = 5 (Saturday)
[,F94]
Time to turn on the AUX output if [,F89] = 5 (Sunday)
Time to turn off the AUX output if [,F89] = 5 (Sunday)
[,F95]
Operating mode for ambient temperature alarms (S1) (0-relative/1-absolute)
[,F96]
[,F97]
Low ambient temperature alarm (S1)
[,F98]
High ambient temperature alarm (S1)
[,F99]
Length of time door is open to trigger alarm
[F100]
Alarm validation time by temperature
[F101]
Alarm inhibit time on power-up
[F102]
Maximum compressor on time without reaching the desired temperature (setpoint)
[F103]
Maximum compressor operating time for maintenance alarm (hour meter)
[F104]
Trigger for alarm when defrosting is over based on time
[F105]
Desired temperature for anti-condensation (sensor 3 heating setpoint)
[F106]
Control differential for anti-condensation (S3)
[F107]
Enables audible alarm (buzzer)
[F108]
High condenser temperature alarm (S3) (visual and audible only)
[F109]
Maximum condenser temperature (S3) to turn off control outputs
[F110]
Control differential for maximum condenser temperature (hysteresis)
[F111]
Time to confirm High pressure alarm
[F112]
Time to confirm Low pressure alarm
[F113]
Time to start delay to monitor low pressure alarm
[F114]
Delay time after high pressure alarm to resume temperature control
[F115]
Delay time after low pressure alarm to resume temperature control
[F116]
Minimum supply voltage (protection)
[F117]
Maximum supply voltage (protection)
[F118]
Voltage indication offset
[F119]
Voltage validation offset
[F120]
Enable logging of HACCP alarms
[F121]
HACCP - Low room temperature alarm
[F122]
HACCP - High room temperature alarm
[F123]
HACCP - Alarm inhibit time
[F124]
Datalogger operation mode
[F125]
Sampling period (time between memory records)
[F126]
Minimal change in room temperature to force write data to memory
[F127]
Variation of digital input or outputs to force writing of data
[F128]
Overwrite old records when memory is full?
[F129]
Digital filter actuation mode
[F130]
Intensity of the digital filter on the room temperature sensor (S1 sensor) (Rising)
[F131]
Intensity of the digital filter on the room temperature sensor (S1 sensor) (Descending)
[F132]
Displacement of the values from the room sensor (S1 sensor)
[F133]
Displacement of the values from the evaporator sensor (S2 sensor)
[F134]
Auxiliary sensor indication offset (S3 sensor)
[F135]
Auxiliary sensor indication offset (S4 sensor)
[F136]
Preferred indication on the display
[F137]
Ambient temperature (S1 sensor) value locked in during defrosting
[F138]
Maximum length of time that the temperature is locked during defrosting
[F139]
Function lock mode
[F140]
Function lock period
[F141]
Turn off control functions
[F142]
Address of the instrument on the RS-485 network
Description
00:00
00:00
00:00
00:00
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0(Off)
0 (Off)
0 (Off)
[F121]
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
-20,1 (Off)
0 (Off)
0 (Off)
CELSIUS (°C)
Min
Max
Unit
Standard
0
-
1
7
hh:mm
00:00
23:59
hh:mm
00:00
24:00 (Off)
24:00 (Off)
23:59
00:00
hh:mm
00:00
24:00 (Off)
24:00 (Off)
hh:mm
23:59
hh:mm
00:00
24:00 (Off)
hh:mm
24:00 (Off)
0
1
-
0
°C
-50,0
105,0
-50,0
°C
-50,0
105,0
105,0
minutes
999
5
minutes
999
0 (Off)
minutes
999
0 (Off)
0 (Off)
999
hours
0 (Off)
9999
hours
1 (On)
0 (Off)
-
°C
-50,0
105,0
30,0
0,1
20,0
3,0
°C
1 (On)
-
1 (On)
°C
105,0
105,0
°C
105,0
105,0
°C
0,1
20,0
3,0
0
seconds
5
60
0
seconds
20
180
seconds
30
600
60
minutes
1
3
10
minutes
1
10
3
10
Vdc
10
40
10
Vdc
40
40
Vdc
-10,0
10,0
0,0
seconds
1
30
5
-
0 (Off)
1 (On)
-50,0
[F122]
°C
-50,0
°C
105,0
105,0
minutes
0 (Off)
999
-
2
2
10
seconds
30
999
°C
10,0
0 (Off)
-
1 (On)
0 (Off)
-
1 (On)
1 (On)
0
-
0
1
seconds
0 (Off)
20
seconds
20
0 (Off)
°C
0,0
20,0
-20,0
°C
0,0
20,0
°C
-20,0
20,0
0,0
-20,0
°C
0,0
20,0
1
-
1
5
0
-
1
2
minutes
999
15
-
0
2
0
seconds
15
60
15
-
2
0 (Off)
-
1
247
1
FAHRENHEIT (°F)
Min
Max
Unit
Standard
0
-
1
7
00:00
hh:mm
00:00
23:59
hh:mm
00:00
24:00 (Off)
24:00 (Off)
00:00
23:59
00:00
hh:mm
00:00
24:00 (Off)
24:00 (Off)
hh:mm
00:00
23:59
00:00
hh:mm
00:00
24:00 (Off)
24:00 (Off)
hh:mm
0
1
0
-
°F
-58,0
221,0
-58,0
°F
-58,0
221,0
221,0
minutes
0 (Off)
999
5
minutes
0 (Off)
999
0 (Off)
minutes
0 (Off)
999
0 (Off)
0 (Off)
0 (Off)
999
hours
0 (Off)
0 (Off)
9999
hours
0 (Off)
1 (On)
0 (Off)
-
°F
-58,0
221,0
86,0
°F
0,1
36,0
5,4
0 (Off)
1 (On)
-
1 (On)
32,0 (Off)
°F
221,0
221,0
32,0 (Off)
°F
221,0
221,0
°F
0,1
36,0
5,4
0
seconds
5
60
0
seconds
20
180
seconds
30
600
60
minutes
1
3
10
minutes
1
10
3
10
Vdc
10
40
10
Vdc
40
40
Vdc
-10,0
10,0
0,0
seconds
1
30
5
0 (Off)
-
0 (Off)
1 (On)
-58,0
[F122]
°F
-58,0
[F121]
°F
221,0
221,0
0 (Off)
minutes
0 (Off)
999
0 (Off)
-
2
2
10
seconds
30
999
°F
0 (Off)
18,0
0 (Off)
-
0 (Off)
1 (On)
0 (Off)
-
0 (Off)
1 (On)
1 (On)
0
-
0
1
0 (Off)
seconds
0 (Off)
20
seconds
0 (Off)
20
0 (Off)
-36,0
°F
0,0
36,1 (Off)
-36,0
°F
0,0
36,0
°F
-36,0
36,0
0,0
-36,0
°F
0,0
36,0
1
-
1
3
0
-
1
2
minutes
0 (Off)
999
15
-
0
2
0
seconds
15
60
15
-
0 (Off)
2
0 (Off)
-
1
247
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the EVOLUTION TC-970E Log+ECO and is the answer not in the manual?

Questions and answers

Keith Stringer
May 1, 2025

The temperature won't drop below 15 degrees F. Is there anything I can do? Also if I turn the control functions off will the compressor keep it frozen?

Related Products for Full Gauge Controls EVOLUTION TC-970E Log+ECO

This manual is also suitable for:

Evolution tc-970e log+eco faston