Vent Configuration - Horizontal Termination - Lopi 864 TV 40K CleanFace Installation Manual

Direct vent fireplace
Table of Contents

Advertisement

Finalizing the Installation

Vent Configuration - Horizontal Termination

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Up to four elbows (45° or 90°) may be used.
Use 8" (203mm) diameter vent (see page for 20 details).
Only one horizontal elbow may be used.
 NG Installations require 1' Vertical Vent Section Directly off Top of Fireplace
 LP Installations require 2' Vertical Vent Section Directly off Top of Fireplace
NOTE: If removing the restrictor, make sure to replace the screws in the firebox ceiling.
21' (6.4m) max
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
© Travis Industries
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 1 (stock)
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
Exhaust Restrictor REMOVED
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
NG INSTALLATIONS - Min. 1' Section
LP INSTALLATIONS - Min. 2' Section
H2
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
H1
6/28/2019 - 1499
(for qualified installers only)
21' (6.4m) max
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbow
25
864 40K CF Install Aust