Problem Areas: Network & Signal
Check:
Inspect the contact pad on the antenna assy and the contact
pin on the PBA.
Action:
1. If dirty or oxidized – clean the pad and pin.
2. If the pad is damaged – replace Rear Cover Assy.
3. Replace PBA.