Problem Areas: Power
Check:
Inspect the battery and the BtB connector of battery to the
PBA.
Action:
1. If not properly connected – disconnect and reconnect.
2. If dirty or oxidized – clean the both sides of the BtB
connectors.
3. If the Battery or its BtB connector is damaged – replace
the Battery.
4. If the BtB connector on the PBA is damaged – replace
PBA.
Check:
Check current draw in off mode by using "Dummy Battery"
(max 1 mA).
Action:
If current draw is abnormal – replace PBA.