Fitting:
•
Place the circuit board on the front housing panel.
•
Secure the circuit board with screws 123, 124 and 125 (fig. 74).
•
Mount connection plugs 2, 3, 9, 14, 15, 16, 17, 18, 19, 20, 21, 22, and 122 onto the circuit board.
•
Mount the facing panel onto the front housing panel, making sure that both lugs 1 lock into place
(fig. 73).
•
Attach the housing insert and secure with both torx screws.
•
Attach the folding cover.
•
After a running-in time of 10 - 15 min. check the adjustment of equal forward and reverse stitch
length in accordance with section 21 of the service manual.