General Installation Information - CVO Fire Compact Fire Ribbon Technical Installation Manual

Table of Contents

Advertisement

General Installation Information

This fire is intended for decorative purposes. The installation must be in
accordance with National Regulations and must be carried out by a qualified
installer.
Clearances between the fire and all combustible materials must conform to
National Regulations.
This fire must be installed and used in accordance with these instructions.
Prior
to
installation,
ensure
that
the
local
distribution
conditions
(identification of the type of gas and pressure and the adjustment of the
appliance) are compatible.
The builders opening or fireplace opening must be constructed of a non-
combustible material.
For some countries a non-combustible hearth must be fitted in front of the
fire in accordance with National Regulations (e.g. United Kingdom).
For some countries a purpose provided air supply must be fitted in
accordance with National Regulations.
Any flue damper plate or flue restrictor must be removed or fixed
permanently in the fully open position, or shall only be fitted in accordance
with National Regulations.
The chimney must be swept before the appliance is installed. The unit must
not be installed unless the chimney/flue length is at least the distance
indicated on page 6 (minimum flue height).
Before the fire is installed a flue test in accordance with National Regulations
should be carried out.
The gas connections must be in accordance with National Regulations.
An isolation valve, or valves, has to be fitted adjacent to the appliance
which, when closed, allow(s) the complete burner and control assembly to
be disconnected for maintenance or repair in accordance with National
Regulations.
The pilot light and flame sensing device fitted to this fire is also an
atmosphere sensing devise. If for any reason any part of the pilot assembly
is to be replaced ALL the assembly including the pilot burner, thermocouple,
electrode and injector must be exchanged complete for an original
manufacturer's pilot assembly only. This atmosphere sensing devise is not
adjustable and must not be put out of action. The pilot light shuts off both
the main burner and pilot if evacuation of the combustion products is
interrupted. If the fire shuts itself off, do not use the fire, and have the flue
and fire checked by a suitably qualified person.