Motor components and options
4.2 Options
Limited validity
Option L03 can be ordered for the above motors in the following version:
● 1FT7 Compact only
● with natural cooling or water cooling
● encoder types used
– with DRIVE-CLiQ AS24DQI and AM24DQI
– without DRIVE-CLiQ: IC2048S/R and AM2048S/R
Option L03 is only available for motors with
● Shaft height 132
● Power connector, size 3
● Power connector with sealing air connection (option Q12)
● Terminal box
● Option "Increased resistance to chemicals" (N16 and N40)
Configuration note
The modified selection and ordering data now apply to all motors with a fixed connector with
sizes 1 and 1.5.
Selection and ordering data:
● 1FT7☐☐☐-5☐☐☐☐-0☐☐☐-Z L03: Fixed connector transverse right
● 1FT7☐☐☐-5☐☐☐☐-1☐☐☐-Z L03: Rotatable connector (for sizes 1 and 1.5 only)
● 1FT7☐☐☐-5☐☐☐☐-2☐☐☐-Z L03: Fixed connector transverse left
● 1FT7☐☐☐-5☐☐☐☐-3☐☐☐-Z L03: Fixed connector axial NDE (from shaft height 100 only)
● 1FT7☐☐☐-5☐☐☐☐-4☐☐☐-Z L03: Fixed connector axial DE
Note
For greater ruggedness when subjected to vibration, we recommend using fixed connectors.