Electrical connection
8.3 System integration
Motors with a DRIVE-CLiQ interface can be connected to the associated Motor Module via a
MOTION-CONNECT cable. The connection of the MOTION-CONNECT cable at the motor
has degree of protection IP67.
NOTICE
Damage to electronic components as a result of electrostatic discharge
The encoder connections have direct contact with electrostatic sensitive devices that can
be damaged or destroyed by electrostatic discharge (ESD).
• Ensure the ESD protection measures are taken (see Equipment damage due to electric
• Only grounded personnel with grounded tools may touch the component connections.
• Heed the EMC information provided by the manufacturer of the converter.
Figure 8-10
Variants of the DRIVE-CLiQ connection
There are two variants of DRIVE-CLiQ connections on the motor:
1 10-pin RJ45plus socket
390
fields or electrostatic discharge (Page 16)).
Encoder interface with DRIVE-CLiQ
RJ45plus socket
Round connector M17
1 round connector M17
Configuration Manual, 09/2018, A5E45099423B AA