Safety Characteristic Data - Pilz PIT js2 Operating Manual

Hide thumbs Also See for PIT js2:
Table of Contents

Advertisement

PIT js2/PIT js2 bc
Pushbutton
Quantity
Relay outputs
Utilisation category of safety con-
tacts
DC1 at
Environmental data
Ambient temperature
Temperature range
Protection type
Housing
Mechanical data
Cable length L1
Cable insulation material K1
Conductor cross section K1
Material
Housing
Dimensions
Height
Width
Depth
Weight

Safety characteristic data

Safety characteristic data
B10d in accordance with EN ISO 13849-1:2015
and EN 62061
Lambda
/Lambda in accordance with EN 62061
d
Operating Manual PIT js2/PIT js2 bc
21130-EN-06
401100
3
401100
24 V
401100
-10 - 55 °C
IP65
401100
5 m
PUR
0,14 mm²
PC-ABS-Blend UL 94V0
341 mm
75 mm
60 mm
837 g
20.000.000
0,10
401101
2
401101
24 V
401101
-10 - 55 °C
IP65
401101
5 m
PUR
0,14 mm²
PC-ABS-Blend UL 94V0
341 mm
75 mm
60 mm
823 g
| 10