Section
CMD
5.4
Cleaning settings:
5.4.1 Counter (days):
5.5
Language settings:
5.6
Unit settings:
5.6.1 Volume:
5.6.2 Temp:
5.7
Time settings:
5.7.1 Year:
5.7.2 Month:
5.7.3 Day:
5.7.4 Format 24h/12h:
5.7.5 Time:
5.8
Download settings:
5.9
Upload settings:
6
Service menu:
6.1
Error list:
6.2
Service counters:
6.3
Calib:
6.3.1 Calibrate flow:
6.3.2 Calibrate temperature:
6.4
I/O test:
6.4.1 Pump:
6.4.2 Float:
6.4.3 W inlet:
6.4.4 Temp:
6.4.5 HW tap:
6.4.6 Relays:
6.4.7 W select:
6.4.8 Descale:
Description
Cleaning setting.
Set after how many days the machine must generate a message for cleaning.
Set the language (if possible to be downloaded using an RFID card when this
language is available).
Volume and temperature setting.
Set the volume unit in ml/l (millilitres/litres) or fl oz/gal (fluid oz/gallons).
Set the temperature unit in °C (degrees Celsius) or °F (degrees Fahrenheit).
Time and date setting.
Set the year.
Set the month.
Set the day (of the month).
Set the format of the clock, 24 hours or 12 hours clock.
Set the time.
Download settings into the machine by means of an RFID card.
Transfer settings from the machine to an RFID card.
Various service settings.
Accessing the service menu requires a code. This is by default set to 0000.
Read the error history.
Read and reset all counter positions.
Calibration menu.
Pump calibration.
Temperature calibration (boiling point determination programme).
Programme for testing various parts.
Pump RPM, Set the pump speed.
Attention! When the speed exceeds a certain value the pump will start moving
water to the filter pan.
FB Pump, feedback from the light sensor on the pump in RPM.
Read if the reed switch of the float is open or closed, this is indicted by "on" or "off".
Read if the inlet valve is open or closed. This is indicated by "on" or "off".
Read the temperature measured by the 3 temperature sensors on the boiler.
Read whether the hot water switch is open or closed.
Switch the hot water valve on and off.
Attention! Make sure that when switching on the hot water valve, water actually
comes out of the hot water tap without operating the hot water lever.
Switch relays and safety relays on and off. The safety relays are on the mainboard.
Set the water selector to the various positions.
Read if the electrodes of the scaling detection make or do not make contact.
23