TROUBLESHOOTING
Fault tracing
Description
The
protection
indicator is
Measurement
ON. The
power
5
source has
no no-load
output.
The display
and the fan
are working
Measurement
properly.
6
The power
source
cannot weld.
0463 714 001
Solution / Remedies
Step 1:
Replace the front panel control PCB.
Step 1:
Set the multimeter to diode test setting, test the voltage drop
of four secondary diodes on the output rectifier board.
If it is over 0.2V, it is normal.
If it is lower than 0.1 V, the secondary diode is defect.
Replace the secondary PCB/Module.
Step 2:
If the main relay on the main control panel is not working,
and the driving is abnormal, the power source will not work.
Replace the main control PCB.
- 50 -