Precor Precision 400 Series Service Manual page 146

Hide thumbs Also See for Precision 400 Series:
Table of Contents

Advertisement

3. Remove the left and right stairarms from the crankarms,
ment" on
page 163.
4. Remove the left and right left and right crankarm assemblies, see
Assembly Replacement" on
5. Remove all tension from the Step-up belt.
a. Use an 11/16" socket to loosen (do not remove) the left and right step-up pulley
shaft nuts.
b. Use a 10 mm wrench to evenly loosen the left and right Step-up belt tension
adjustment nuts. Completely remove all tension and provide as much slack as
possible.
6. Use a 1/2" wrench to loosen the drive belt idler pulley nut and remove all tension from
the input drive belt.
7. Remove the left and right pillow block bearings, see
ment" on
page 155. Retain part(s) and/or fastener(s) for installation.
8. Slide the input drive assembly through the step-up and drive belts and remove.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
page 151.
6 Available Replacement Procedures
Input Drive Assembly Replacement
"Stairarm Assembly Replace-
"Crankarm
"Pillow Block Bearing Replace-
Page 138

Advertisement

Table of Contents
loading

This manual is also suitable for:

Precision efx400-14Precision efx400-18

Table of Contents