Stationary Mounting Layout
Plan the layout for easy operator access to the
pump air controls, leave sufficient room to change
drums, and mount on a secure platform.
For ease in changing drums, install a pump
elevator.
air hose coupling
drum cover
air hose
hold-down bracket
vent hose
(high-pressure
grease hose)
follow plate
(optional)
vent tube
hold-down rod
hold-down lug
Fig. 2
Installation
Open Drum, Cover-Mounted Pumps
See Fig. 2.
1. Remove the original drum cover.
2. Place the new drum cover on the drum. Carefully
guide the pump riser tube through the mounting
gasket, and fasten the pump to the drum cover
such that the outlet of the pump is 90 counter-
clockwise from the hole with the grommet.
3. For Models 240–854 and 240–857, install the
Hold-Down Kit according to the instruction in the
Drum Mounting With Hold-down Kit section on
page 9.
4. Install and tighten the bolts that secure the pump
to the drum cover.
air hose
tee
vent valve
high-pressure grease hose
Hold-Down Kit Part Numbers:
Vent Valve Kit Part Numbers:
Optional Follow Plate Part Numbers:
Drum Cover Part Numbers:
Model No. 240–857 shown
For 120# barrel: 222–061
For 70# barrel: 240–671
For Fire-Ball Model 240–857: 240–760
For Fire-Ball Model 240–854: 240–761
For President Model 240–848: 240–763
For 70# and 120# barrel: 240–457
For 400# barrel: 240–459
For Fire-Ball Models: 240–668
For President Model: 240–666
8449B