LED
T1
T2
T3
PRIMA / PRIMA MAXI
T1 : deadbolt closure timing upon approach of the door.
T2 : deadbolt closure timing if the door is not opened.
T3 : timing of prolonged door opening alarm (only on versions
246-248-266-268).
With T1 and T2 set to 0 sec : internal timings disabled, the lock can be
operated by means of external control systems by supplying or removing power.
The function of the magnetic door sensor is also disabled.
With T3 set to 0 sec : the alarm feature for prolonged opening is disabled.
To check the current timing: briefly press the concerned button.
Button
T1
T2
0 to 60 sec.
T3
0 to 120 sec.
BUTTONS
T3
T2
T1
LED
PRIMA OP
Range
0 to 5 sec.
T1
LED
Minimum range
±1 sec.
± 5 sec.
±10 sec.
T2
T3
CLASSICA
Default setting
1 sec.
5 sec.
10 sec.
15