Kutai electronics ADVR-053 Operation Manual

Kutai electronics ADVR-053 Operation Manual

Universal hybrid analog-digital voltage regulator

Advertisement

Quick Links

ADVR-053
Universal Hybrid Analog-Digital
Voltage Regulator Operation Manual
Self Excited 5 Amp Analog / Digital Voltage Regulator
For shunt and auxiliary windings generators
With over-excitation and lost of sensing protection
Headquarters : No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung, TAIWAN
Tel : + 886-7-8121771
Fax : + 886-7-8121775
URL : http://www.kutai.com.tw

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVR-053 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kutai electronics ADVR-053

  • Page 1 ADVR-053 Universal Hybrid Analog-Digital Voltage Regulator Operation Manual Self Excited 5 Amp Analog / Digital Voltage Regulator For shunt and auxiliary windings generators With over-excitation and lost of sensing protection Headquarters : No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung, TAIWAN...
  • Page 2: Section 1 : Summary

    SECTION 1 : SUMMARY The ADVR-053 is an advance (Hybrid Analog / Digital added over excitation and loss of sensing shutdown Voltage Regulator) design general-purpose protections, with matching U/F, O/E LED indicator isochronous stand alone applications. The ADVR-053 lights. Consequently, this AVR prevents the generator...
  • Page 3: Section 3 : Wiring

    (on a auxiliary powered AVR) , the to 300 Vac shunt or auxiliary windings. excitation voltage rapidly increase, causing severe damage to the AVR or exciter. The Power Input Voltage Selection ADVR-053 over excitation protection If generator rated voltage is 220 Vac (Line to line shutdown that cuts excitation at once.
  • Page 4: Section 7 : Startup Adjustment

    8.2.2 Restart generator and measure the residual voltage by AC Voltmeter, if it is still less than 5 Vac, repeat the previous process, after several times, the residual voltage still cannot be built, Kutai EB500 is strongly recommended, see Figure 1. ___________________________________________________________________________________________ ADVR-053...
  • Page 5: Section 9 : Trouble Shooting

    2. All voltage readings are to be taken with an average-reading voltmeter. SECTION 10 : FIGURE AND SIZE 75.0 48.5 59.0 15.5 Field 1000 OHM EXT. VR STAB VOLT EXT.VR SW-2 ON 170  260 Vac Figure 2 Figure 3 ___________________________________________________________________________________________ ADVR-053...
  • Page 6 EXT. VR STAB VOLT U/F STAB VOLT Figure 6 With Aux. Winding Figure 7 ※ Use only replacement fuses specified in this user manual. ※ Appearance and specifications of products are subject to change for improvement without prior notice. ___________________________________________________________________________________________ ADVR-053...

Table of Contents